- 37: temp_rh, Site stn6, Tue 01-Aug-2000 17:19:59 PDT, TRH Swapped
The previous sensor was reporting bad temps (extremely high) during the
day. The spare trh was installed.
Old: s/n 1 (ie not reporting actual board #)
New: s/n 704
Note: 704 had been reported as not working on the sbus although it was
today. Keep an eye on it...
PS. 3 Aug by spo:
The new sensor has been working fine.
- 76: radiation, Site stn6, Fri 11-Aug-2000 10:01:09 PDT, KZ at station 6 removed
The problem with the KZ seems to be in the
sensor so I brought it back to the base. I
was out there at the site from 9:20 - 9:40
local time.
- 77: radiation, Site stn6, Fri 11-Aug-2000 10:24:38 PDT, KZ fixed at station 6
The KZ at station 6 is back up, ~10:40 local. The
internal connector was bad. removing the shrink tubing
near the connector fixed the problem so I left the
connector in place. My guess is the contacts between
male and female have opened up and little bit of twist
on the cable causes and open circuit.
- 87: sonic, Site stn6, Sun 13-Aug-2000 09:46:32 PDT, Shadow correction turned off on sonic at station 6 at 9:20 local
The shadow correction was turned off on sonic at station 6.
The parameters settings:
MAX_CORRECT = .84
CORRECT_ADJUST = .16
CORRECT_ANGLE = 70
This is sonic #980505, ATI K probe
- 97: adam_eve, Site stn6, Mon 14-Aug-2000 12:16:01 PDT, Station 6 down, ~1:40 am
Station 6 went down this morning, ~1:40 local. Upon inspection,
there was not power getting to the station. I will work on it
now that 3 has been moved.
- 98: adam_eve, Site stn6, Mon 14-Aug-2000 13:01:14 PDT, Station 6 up, ~12:50
Station 6 is running again. The problem was that there was no voltage coming
from the battery box. The problem was solved by yanking everithing.
In other words, who knows, it's working again...
- 103: adam_eve, Site stn6, Tue 15-Aug-2000 08:44:00 PDT, Station 6 archive and covar not running
Covar and Archive were not running for station 6.
This dates back to the crash yesterday. It is now running
at ~8:30 local.