EBEX00: Logbook Entries

EBEX00: Site stn6 Messages, 7 Entries..

Return to Logbook Contents Page
Entry Date Title Site Author #Graphics
37 Tue 01-Aug-2000TRH Swappedstn6militzer
76 Fri 11-Aug-2000KZ at station 6 removedstn6semmer
77 Fri 11-Aug-2000KZ fixed at station 6stn6semmer
87 Sun 13-Aug-2000Shadow correction turned off on sonic at station 6 at 9:20 localstn6semmer
97 Mon 14-Aug-2000Station 6 down, ~1:40 amstn6semmer
98 Mon 14-Aug-2000Station 6 up, ~12:50stn6ribeiro
103 Tue 15-Aug-2000Station 6 archive and covar not runningstn6semmer


37: temp_rh, Site stn6, Tue 01-Aug-2000 17:19:59 PDT, TRH Swapped
The previous sensor was reporting bad temps (extremely high) during the
day.  The spare trh was installed.
Old: s/n 1 (ie not reporting actual board #)
New: s/n 704
Note: 704 had been reported as not working on the sbus although it was
      today.  Keep an eye on it...

PS. 3 Aug by spo:
The new sensor has been working fine.

76: radiation, Site stn6, Fri 11-Aug-2000 10:01:09 PDT, KZ at station 6 removed
The problem with the KZ seems to be in the
sensor so I brought it back to the base. I
was out there at the site from 9:20 - 9:40
local time.

77: radiation, Site stn6, Fri 11-Aug-2000 10:24:38 PDT, KZ fixed at station 6
The KZ at station 6 is back up, ~10:40 local. The
internal connector was bad. removing the shrink tubing
near the connector fixed the problem so I left the
connector in place. My guess is the contacts between
male and female have opened up and little bit of twist
on the cable causes and open circuit.


87: sonic, Site stn6, Sun 13-Aug-2000 09:46:32 PDT, Shadow correction turned off on sonic at station 6 at 9:20 local
The shadow correction was turned off on sonic at station 6.
The parameters settings:
	MAX_CORRECT = .84
	CORRECT_ADJUST = .16
	CORRECT_ANGLE = 70

This is sonic #980505, ATI K probe




97: adam_eve, Site stn6, Mon 14-Aug-2000 12:16:01 PDT, Station 6 down, ~1:40 am
Station 6 went down this morning, ~1:40 local. Upon inspection,
there was not power getting to the station. I will work on it
now that 3 has been moved.


98: adam_eve, Site stn6, Mon 14-Aug-2000 13:01:14 PDT, Station 6 up, ~12:50
Station 6 is running again. The problem was that there was no voltage coming
from the battery box. The problem was solved by yanking everithing.

In other words, who knows, it's working again...
103: adam_eve, Site stn6, Tue 15-Aug-2000 08:44:00 PDT, Station 6 archive and covar not running
Covar and Archive were not running for station 6.
This dates back to the crash yesterday. It is now running
at ~8:30 local.