- 34: radiation, Site stn3, Mon 31-Jul-2000 13:33:28 PDT, Rsw.out.kz work
07/31/00
The Kipp&Zonnen has been providing bad data through the night and
into the day. During the day after warming up, the data has been
OK. The wiring inside the ventillation plenum had a bad connection.
It was recabled and now appears OK.
The wiring arrangement for the K&Z radiometers needs to be improved.
- 51: temp_rh, Site stn3, Fri 04-Aug-2000 19:07:23 PDT, TRH swap / Possible EVE problems
The TRH has not been working for a few days.
Arriving at station confirmed no reply on the sbusdebug.
Attempted to 'stop' eve and got:
memPartFree: Invalid block 0x157d04 in partition 0x70392
at that point the watchdog/reset board did it's thing but the
reboot failed with the same errors
memPartFree: Invalid block 0x16b078 in partition 0x70392
power cycling the box brought everything back up including the
trh.
To be on the safe side I swapped the trh anyway
Old TRH: #702
New TRH: #703
Possible EVE memory problem:
The trh was down during the hot part of the day during the last 4
days.
Note: This station has the eve electronics box mounted laying down
rather than the normal upright configuration. This could
increase the heating on the eve boards.
- 95: adam_eve, Site stn3, Mon 14-Aug-2000 07:46:57 PDT, Station 3 moving
Steve and Tomas have decided to move station 3
to the north field. The station will be down
for most of the morning.
- 96: adam_eve, Site stn3, Mon 14-Aug-2000 12:15:20 PDT, Station 3 at new site
Station 3 is now at the new site and is up and running.
- 100: radiation, Site stn3, Mon 14-Aug-2000 17:29:23 PDT, Clean domes & krypton at 3
Due to the move the domes and krypton needed cleaning.
This was done at ~17:15 local.