- 272: FASTH2O, Site , Wed 24-Nov-1999 16:43:02 MST, Krypton & Ophir operations summary
From logbook, a list of actions for each station's fast H2O sensors:
(now, NetCDF files should NA fill the bad times)
[Kryptons]
Site 1:
4/12 1725 install
4/27 1850 unbag
4/27 1923 clean
5/1 1708 bag
5/2 2029 unbag
5/8 1946 (plugged?) & cleaned
5/10 2129 "work"
Thus, working: 4/27 - 5/1; 5/2 - end
Site 2:
4/12 2030 install
4/19 2010 new bag
4/27 1843 unbag
5/1 1743 bag
5/2 2132 unbag
5/8 1722 clean
Thus, working: 4/27 - 5/1; 5/2 - end
Site 3:
4/16 1944 cleaned [I think this time is CDT, when others are GMT 6/5/00]
4/27 1738 unbag
4/27 2008 clean
5/1 1726 unplugged (& bagged?)
5/2 1701 reconnect
5/6 1802 unplugged
5/9 2202 routine [kh2o turned on ~5/8 2200]
5/13 1917 cleaned
Thus, working: 4/27 - 5/1; 5/2 - 5/6; 5/9? - end
Site 4:
4/12 1813 install & bag
4/27 1528 unbag
5/1 1914 bag
5/2 1903 bag and clean?
5/6 1902 unplugged
5/9 1350 plugged
5/19 1543 died last night [about 0700]
Thus, working: 4/27 - 5/1; 5/2 - 5/6; 5/9 - 5/19
Site 5:
4/10 1721 setup
4/27 2010 cleaned
5/1 1703 bagged & unplugged
5/2 1757 unbagged
5/6 1656 unplugged
5/9 2236 routine visit [kh2o on about 5/8 2200]
5/19 1656 died [about 0800]
Thus, working: 4/27 - 5/1; 5/2 - 5/6; 5/9? - 5/19
Site 6:
4/10 2225 changed
4/11 1429 bagged
4/12 2026 new sensor
4/19 1654 moved, cleaned & bagged
4/22 1839 rotated
4/27 1637 unbag
4/27 2156 cleaned
5/1 1455 bagged
5/2 1558 unbagged & cleaned
5/6 1942 unplugged
5/9 2019 routine [kh2o on about 5/8 2200]
Thus, working: 4/10 - 4/11; 4/12 - 4/19; 4/27 - 5/1; 5/2 - 5/6; 5/9? - 5/19
[Ophirs]
Site 7:
4/19 1702 moved
4/24 1828 changed cables
4/24 2011 working
Thus, Ophir working: 4/19+ - end
Site 8:
4/24 1828 changed cables
4/24 2011 working
5/11 1600 install krypton
5/19 1522 krypton died
Thus, Ophir working: 4/24 - end; krypton working 5/11 - 5/19
- 230: FASTH2O, Site all, Mon 19-May-1997 15:22:27 GMT, Krypton hygrometers appear to have failed at 4,5,8
The Krypton hygromterers at stations 4,5, and 8 appear to have quit.
John and Kathy will try to revive them and Peggy is considering
moving working hygrometers.
- 197: FASTH2O, Site 8, Sun 11-May-1997 21:45:40 GMT, Installed AIR bph and CSI Krypton
Installed the AIR bandpass on the ATI tower and the CSI Krypton
sensor on the Campbell tower this afternoon. Each sensor was
installed underneath the sonic boom and "behind" the sonic.
Calibration for Krypton:
Added file $ASTER/cal_files/krypton1089
and edited $ASTER/projects/CASES97/ops1/prep.config
for marigold 100 q_kh2o("krypton1089") d=(h2o).csi
and restarted the covars.
NOTE in the krypton1089 file I put in the "Full Range"
coefficients instead of the Dry or Wet linear range.
...I presume that's correct?
These coef. were found on the Campbell worksheets
provided when the sensors were rented for this project.
Calibration for BPH with AIR fast trh:
Steve edited $ASTER/projects/CASES97/ops1/prep.config
for marigold 101 t_vaisala(-41.731524,20.5538,-0.006932) d=(t).bph.s8
and marigold 102 h2o_vaisala(2.646416,17.16,0.519267,0.0,0.0)
d=(rh,h2o,rh2o).bph.s8
and restarted covars on 5/12: 14Z
- 147: FASTH2O, Site all, Thu 01-May-1997 19:11:47 GMT, Bagged krypton sensors
Bagged krypton h2o sensors at sites 1-4, 6;
disconnected krypton at site 5 from station electronics
and inserted shorting plug in A/D input channel.
- 98: FASTH2O, Site 8, Thu 24-Apr-1997 20:11:41 GMT, Both OPHIRS now up
We found a miswired cable by comparing the two serial ophir cables.
Both instruments are now running as they should.
- 97: FASTH2O, Site 8, Thu 24-Apr-1997 18:28:21 GMT, OPHIR cable problem
We've isolated the problem with the OPHIR at #8 to the serial cable.
We've pulled the cable from #7 to allow us to compare the two.
Hopefully, both will be up soon.
- 65: FASTH2O, Site 7, Sun 20-Apr-1997 19:52:49 GMT, modified ophier calib routine
I've noticed that the ophir data from site 7 (the only ophir so far) have had
a lot of spikes. They are of two types: zero values and double values.
I've isolated the double value glitches to an occasional "stuck bit" in
the reference measurement, with values off by 256 counts.
I've added simple despiking of this channel into the ophir calibration
routine which appears to fix this problem, though I haven't tested it
through zero values.
- 52: FASTH2O, Site 7, Sat 19-Apr-1997 17:02:51 GMT, ophirs moved
the ophirs at sites 7 and 8 were moved closer to the tower along their
booms. This was done to reduce the moment for wind loading of the towers
(they were swaying a lot yesterday) and to reduce the blockage for N winds.
They are now about 70cm to the NE of the sonic arrays.