- 240: SONIC, Site 4, Tue 20-May-1997 22:31:08 GMT, ati sonic was being interfered with by pam guy wire
the guy wire was caught against the "v" vector of the ati sonic - the ati
was freed at 20:35
- 229: SONIC, Site 8, Mon 19-May-1997 14:50:14 GMT, Campbell Sonic Restarted
The Campbell Sonic hung last night.
Restarted the data output via simple "rserial marigold 206"
and issuing serial command. In this case i used the 'P'
instead of the 'W' but it seemed to work just as well.
Down: 10:15Z, (5:15 CDT)
Up: 14:15Z, (9:15 CDT)
The sonic temperature from the Campbell has intermittent
spikes that do not look real. twh
- 159: SONIC, Site 8, Sat 03-May-1997 15:21:15 GMT, Power cycled on Campbell Sonic at 9:09 local (14:09 GMT)
The sonic had to have its data output restarted manually after the power
down/up. This was done by an "rserial marigold 206", command to talk to
the sensor. Typing a "w" started the data rolling again.
- 140: SONIC, Site all, Wed 30-Apr-1997 20:59:37 GMT, Sonic boom heights & Distances
Sonic boom heights:
Station 1 94 in (239 cm) Solent
Station 2 94 in (239 cm) Solent
Station 4 127 in (322 cm) ATI
Station 6 107 in (271 cm) Solent (22 in above boom)
Station 6 132 in (335 cm) Solent raised May 7
Station 8 400 cm ATI
Sonic distance from Kh20
Station 1 60.5cm
Station 2 50.9cm
Station 3 na
Station 4 57cm
Station 5 na
Station 6 24"
Station 7 na
Station 8 na