Graphic: |
Arrived 16:11
A series of tests were carried out to determine and reduce Kr signal noise
The fast data was acquired for later analysis (logged as s7.020610):
- Battery pack ( 1.61v ) to AMP-9 - Good ~ 8035
- Battery pack to serial A/D - Good ~ 16065
- Kr 1394 installed (head in zip-log bag); wired directly to A/D (lots of
GOES noise)
17:00 disconnected the grey cable from Kr box and reconnected using
red cable (better shielding?)
17:05 removed plastic bag covering Kr head
- connected via front panel
Turned off station and re-did GOES shielding (twisted wires vs. clip leads to
ground, shielded GOES transmitter power as well). Noise now ~80,
A crudely-annotated plot of the above data is attached.
Conclusion: most of the "noise" seen on this station was still GOES
interference. I've significantly reduced it, but it is still present.
Time will tell if 1394 behaves better at this station than its former location
at s9. It checks out okay in the lab (13mA, 1.7V in dry air -- even
better than 1392 that just came back from Campbell) and I've just replaced
the 4-pin connector which had a small amount of white corrosion. Nevertheless,
I don't have much confidence that the connector change will fix the low-noise
problem.
Changed station configuration to use kry1394s.dat calibration file.
Departed 17:38
228: Site_visit, Site 7, Sun 09-Jun-2002 18:52:40 CDT, Site 7 visit
Arrived 14:12
Set GOES transmission time.
Exchanged serializer and examined noise:
Didn't have a working CSAT-1 serializer in the spare box :(, also the A/D
from the one CSAT-1 spare didn't work with the CSAT-1 CPU in the box.
Thus, changed to a configuration with the old CSAT-1 CPU and the A/D from
the UW-1 that we removed from s9 yesterday. The reference voltages were
nearly the same -- the CPU is -88 and the A/D is -86. I left it this way.
I used "fastsave" to examine the data, expecting a good result to be a large
reduction in h2o'h2o'.
h2o w'h2o' h2o'h2o'
17.82 0.029 0.145 before changes; obviously bad
17.91 0.023 0.199 "
18.24 0.023 0.028 change to -86 A/D; (short fastsave)
18.02 0.012 0.264 " (normal length fastsave)
18.03 -0.001 0.336 "; reseated all connectors on EVE and also
changed to spare Krypton signal cable
Obviously, none of these changes improved matters. I went back to the normal
cabling, though I left the -86 A/D board in place.
The only thing I can think of next is to work on the front panel itself!
Removed Kr 1393 for transport to station 8 for tests
Depart 15:21
223: Site_visit, Site 7, Sat 08-Jun-2002 23:22:32 CDT, Site 7 visit
[A series of visits to isolate problem with krypton fluxes;
back to s7 to install s8's krypton]
Arrive: 1745
- installed kypton 1393 box and head
Depart: 1757
NOTE: Didn't change calibration files -- station is still using 1391
calibrations (but good enough for these tests?)
220: Site_visit, Site 7, Sat 08-Jun-2002 23:11:47 CDT, Site 7 visit
[A series of visits to isolate problem with krypton fluxes;
s7 visit to remove krypton; also change CR10 power; also calibrate PIR]
Arrive: 1311
- clean radiometers; start shading tests, though scattered clouds, 2x 60s each
captured to s7l.020608
- removed krypton 1391 at 1320
- moved GOES antenna back from SE to SW tripod leg (where we had put it during
the GOES interference tests a while ago)
- CR10 power to standalone battery
- copied /card
Depart: 1340
198: Site_visit, Site 7, Thu 06-Jun-2002 10:44:49 CDT, Site 7 visit
[This typed in 6 Jun for stuff done 5 Jun since I was too soggy yesterday.]
Peggy Lemone and Fei Chen visited yesterday. I took them to sites 7,9,8 while
I rehung krypton electronics (which were cleaned up and had new 6-pin connectors
installed in the trailer) in plastic boxes and downloaded /card. All of these
were serviced by climbing -- the towers were not dropped.
It was raining during all of these visits, so all kryptons were wet. All
krypton signals were only ~30mV -- hopefully they will recover.
I intended to do the logger power rewiring at s7 and s9, but forgot to bring
power cables :(
Approximate times were:
s7: 1340-1420 (drove in -- Peggy walked)
s9: 1530-1600 (started to drive in, got stuck in the mud!)
s8: 1630-1700 (walked in) had error downloading /card; DID NOT GRAB SDR
191: Site_visit, Site 7, Tue 04-Jun-2002 18:23:24 CDT, Site 7 visit
Arrived in heavy rain at 14:40.
Drove only to gate. Steve ran to station, climbed up and removed Kr electronics
Departed at 15:00
161: Site_visit, Site 7, Wed 29-May-2002 23:19:08 CDT, Site 7 visit
We did several things at site 7. Our primary reason for the visit was to see
if the glitch in the analog channels seen in the high-rate data at s8 also
occurred at non-supersites. Using "sbusdebug" to watch Tsfc voltages, it was
obvious that the glitch does occur here. The counts = 0.1mV changed by ~250
when the GOES transmitter was on. I captured a bit of this on the Panasonic
using minicom (this file is now in $PAM/projects/IHOP02/captures/s7.020529).
We further found out
by attaching the dummy RF load that this problem disappears. Thus, it is an
RF interference problem. We moved the antenna from the SW to E leg of the
tripod, but this didn't appear to work. (Note that we left it in this position
which is rather close to the sonic.) During the process, I rebooted a few
times and even powered-off the station once. Note that the /card data should
recover much of the data while the GOES was off.
We left the station with GOES back running and the antenna near the sonic.
During all of this, an EVE error started appearing: "Illegal Address, 21 ticks".
Since all of the data channels appeared to be working, we ignored this.
Also, it seemed to me that the CR10x data didn't get started after one of the
reboots, so I used "lineon 2"; "lineoff 2" to get it going again. I'm assuming
that this really wasn't necessary.
158: T_RH, Site 7, Tue 28-May-2002 16:51:57 CDT, Replaced TRH206 w/TRH003
Replaced TRH206 w/ TRH003. TRH206 blew the Sbus fuse. It is a 2 amp
fuse, but none was available, so I replaced it with a 3 amp fuse.
Downloaded local storage.
157: Fast_KH2O, Site 7, Tue 28-May-2002 16:50:27 CDT, Resealed KH2O, Station 7
Opened KH2O electronics and was corroded again. Cleaned internal
power connector terminals and applied Seal & Peel to internal
connectors. Cleaned KH2O windows.
156: Site_visit, Site 7, Tue 28-May-2002 16:45:43 CDT, Site 7 visit
Visited site 7, 1220-1505 CDT, May 28
Replaced TRH206 w/ TRH003. TRH206 blew the Sbus fuse. It is a 2 amp
fuse, but none was available, so I replaced it with a 3 amp fuse.
Downloaded local storage.
Opened KH2O electronics and was corroded again. Cleaned internal
power connector terminals and applied Seal & Peel to internal
connectors. Cleaned KH2O windows.
Tightened terminal screws in Campbell data logger enclosure.
129: Site_visit, Site 7, Sat 25-May-2002 12:09:54 CDT, Site 7 visit, May 16
TWH extracted the following from Josh Uebelherr and Joseph Alfieri
email recieved 5/25/02
8) Site 7: 5/16/02
Arrival: 1550
Departure: 1705
Conditions: heavy overcast, light NE winds, light 'sprinkle of rain for
about ten minutes at 1705
-Radiometers cleaned at 1700, some dust on domes prior to cleaning
-Gravimetric soil core taken at 1654
-Cuttings of the representative species to be used for porometry were
taken for identification purposes.
126: Site_visit, Site 7, Sat 25-May-2002 12:06:41 CDT, Site 7 visit, May 15
TWH extracted the following from Josh Uebelherr and Joseph Alfieri
email recieved 5/25/02
5) Site 7: 5/15/02
Arrival: mid-afternoon
Departure: mid-afternoon
-No maintenance or measurements performed, only visited site for survey
with David Yates to discuss surface characterization and sampling method
109: Site_visit, Site 7, Tue 21-May-2002 16:39:17 CDT, Site 7 visit
Tom visted site 8 1455 - 1515 CDT, May 21
Took site photographs. First took two pictures of site from SE, then
two consecutive series of photos from next to the tripod at 45 degree
azimuth intervals, starting from North and proceeding clockwise
through E,S,W,N.
103: EVE, Site 7, Mon 20-May-2002 09:22:34 CDT, Replaced EVE prom at station 7
Replaced EVE prom EVE 4/21/02 6047 with IHOP02 5/14 0xA7BA
100: Fast_KH2O, Site 7, Mon 20-May-2002 09:14:53 CDT, Cleaned kh2o sensor at station 7
Tom cleaned the windows on the kh2o sensor head and opened the
electronics box to clean the internal connectors on the bulkhead
power connector. The latter were corroded. Used Peel and Seal to
seal the electronics box.
99: Site_visit, Site 7, Mon 20-May-2002 09:10:23 CDT, Site 7 visit
Tom visted site 7 2:45 - 4:45 pm CDT, May 19.
Cleaned the kh2o head and the power connector inside the electonics
box, reset the GOES clock, and downloaded the local data storage.
Replaced EVE prom EVE 4/21/02 6047 with IHOP02 5/14 0xA7BA
Measured multiplexer and CR10 supply voltages: 14.0 V
53: Loggers, Site 7, Sun 12-May-2002 15:38:17 CDT, Checked logger coefficients at station 7
Checked logger coefficients at Site 7.
They were as listed in logbook entry 20.
37: Status, Site 7, Tue 07-May-2002 21:04:19 MDT, site 7 setup
Site 7 was completed yesterday.
Sonic serial number: 539
Sonic Height: 2.7 m
Sonic Direction: 92 degrees
Krypton serial number: ????
Tsfc serial number: 3577-6
TRH serial number: 206
Prop serial number: 00318
Prop direction: 175 degrees
Radiation height: 2.2 m
Profile box: 10
NOTE: No krypton has been setup here yet.
20: Loggers, Site 7, Thu 25-Apr-2002 14:21:54 MDT, CR10X coefficients for station 7
Coefficients downloaded to the
CR10x logger at station 7:
Q7-97035 NET(A+) 00 9.26
x A- 01 11.52
E-29137 PYGIN 02 246.9135802
NA PYGOUT 03 0
E-26235 PSPIN 04 111.7318436
NA PSPOUT 05 0
H-983212 x 06 38.4
PAR-Q9125 x 07 .238563277
Pin-Tcase A0 10 -35.3986664
x A1 11 71.5120618
x A2 12 -28.527393
x A3 13 7.5105057
x A4 14 .5295503
Pin-Tdome A0 15 -35.671396
x A1 16 71.415322
x A2 17 -28.56534
x A3 18 7.592893
x A4 19 .499873
Pout-Tcase A0 20 0
x A1 21 0
x A2 22 0
x A3 23 0
x A4 24 0
Pout-Tdome A0 25 0
x A1 26 0
x A2 27 0
x A3 28 0
x A4 29 0
TS-NCAR001 A0 30 -240.18024
x A1 31 228.29406
x A2 32 10.24176
MS-010 A0 45 -.187
x A1 46 .037
x A2 47 .335
E-29137 x 51 246.9135802
NA x 52 0
E-26235 x 53 111.7318436
NA x 54 0
Pin-Tcase A0 55 -35.3986664
x A1 56 71.5120618
x A2 57 -28.527393
x A3 58 7.5105057
x A4 59 .5295503
Pin-Tdome A0 60 -35.671396
x A1 61 71.415322
x A2 62 -28.56534
x A3 63 7.592893
x A4 64 .499873
Pout-Tcase A0 65 0
x A1 66 0
x A2 67 0
x A3 68 0
x A4 69 0
Pout-Tdome A0 70 0
x A1 71 0
x A2 72 0
x A3 73 0
x A4 74 0
ACTIVE x 99 0
Post IHOP coefficients downloaded from cr10x
00:+9.2600
01:+11.520
02:+246.91
03:+0.0000
04:+111.73
05:+0.0000
06:+38.400
07:+.23856
10:-35.399
11:+71.512
12:-28.527
13:+7.5105
14:+.52955
15:-35.671
16:+71.415
17:-28.565
18:+7.5929
19:+.49987
20:+0.0000
21:+0.0000
22:+0.0000
23:+0.0000
24:+0.0000
25:+0.0000
26:+0.0000
27:+0.0000
28:+0.0000
29:+0.0000
30:-240.18
31:+228.29
32:+10.242
45:-.18700
46:+.03700
47:+.33500
51:+246.91
52:+0.0000
53:+111.73
54:+0.0000
55:+0.0000
56:+1.0000
57:+0.0000
58:+0.0000
59:+0.0000
60:+0.0000
61:+1.0000
62:+0.0000
63:+0.0000
64:+0.0000
65:+0.0000
66:+0.0000
67:+0.0000
68:+0.0000
69:+0.0000
70:+0.0000
71:+0.0000
72:+0.0000
73:+0.0000
74:+0.0000
99:+0.0000
|