Entry
| Date
| Title
| Site
| Author
| #Graphics
|
309 | Sat 19-Aug-2006 | Rain gauge test tip | 9 | ideris
|
308 | Sat 19-Aug-2006 | Rnet cleaned | 9 | ideris
|
307 | Sat 19-Aug-2006 | station visit, site 9, August 19 | 9 | ideris
|
253 | Thu 10-Aug-2006 | Site visit, site 9 | 9 | oncley
|
241 | Tue 08-Aug-2006 | net radiometer cleaned | 9 | maclean
|
240 | Tue 08-Aug-2006 | Rain gauge tilted, Aug 8 | 9 | maclean
|
239 | Tue 08-Aug-2006 | Station visit, site 9, Aug 8 | 9 | maclean
|
180 | Tue 25-Jul-2006 | Station visit site 9: rain tip | 9 | horst
|
178 | Tue 25-Jul-2006 | Station visit site 9: cleaned net radiometer | 9 | horst
|
177 | Tue 25-Jul-2006 | Station visit site 9: data system, GOES, fence | 9 | horst
|
143 | Wed 19-Jul-2006 | St 9 Visit: GOES outage | 9 | militzer
|
116 | Sat 15-Jul-2006 | St 9: Site maintenance and electric fence install | 9 | poulos
|
76 | Sat 08-Jul-2006 | st9 Visit: Rnet leveled | 9 | militzer
|
43 | Wed 05-Jul-2006 | st9 visit: goes power level | 9 | militzer
|
42 | Wed 05-Jul-2006 | st9 visit: boom angle | 9 | militzer
|
41 | Wed 05-Jul-2006 | st9 visit: new software | 9 | militzer
|
- 309: rain, Site 9, Sat 19-Aug-2006 16:48:15 MST, Rain gauge test tip
1 test tip at 14:53.
- 308: radiation, Site 9, Sat 19-Aug-2006 16:47:36 MST, Rnet cleaned
Rnet cleaned at 14:51, appeared clean
- 307: LOG, Site 9, Sat 19-Aug-2006 16:45:22 MST, station visit, site 9, August 19
A.J.I. and Steve S. arrived at 14:50 and left at 15:10
Activities:
- Cleaned Rnet at 14:51, appeared clean
- 1 test tip at 14:53
- 253: LOG, Site 9, Thu 10-Aug-2006 23:57:46 MST, Site visit, site 9
visit to site 9 from about 0120-0140Z
Activities:
- swap usb stick
- install new software
- fix electric fence (trashed again!)
- 241: radiation, Site 9, Tue 08-Aug-2006 15:09:36 MST, net radiometer cleaned
Clened the net radiometer sometime during the visit today, Aug 8
between 10;45 and 11:15. The unit has a small dimple in the dome.
- 240: rain, Site 9, Tue 08-Aug-2006 15:04:22 MST, Rain gauge tilted, Aug 8
Rain gauge at this site was tilted about 10 to 15 degrees.
Probably nudged by a cow.
There was rain measured at this site yesterday, Aug 7, so
perhaps the tilt was not enough so that water spilled
from the tipper.
Tested gauge with 2 tips, at 11:10, Aug 8.
- 239: LOG, Site 9, Tue 08-Aug-2006 14:56:59 MST, Station visit, site 9, Aug 8
Routine site visit. Arrived 10:45 MST. Oncley, Maclean.
Visitor: Susanne Grossman-Clarke from ASU.
Installed new software, but ntpq was not installed due to script
goofup.
Top wire of electric fence was largely off the posts - cows have
frequented this site, but no damage other than a tilted rain gauge.
Guyed corner posts of fence. Swapped e-fence battery, voltage was
11.7V. New battery: 12.6V.
Cleaned net radiometer. Small dimple in dome.
2 test tips of rain gauge.
Swapped usbdisk.
This is data box #12, goes model 120.
Left 11:15.
- 180: rain, Site 9, Tue 25-Jul-2006 17:59:21 MDT, Station visit site 9: rain tip
Inspected rain gauge: no varmints
Recorded one tip for test.
- 178: radiation, Site 9, Tue 25-Jul-2006 17:57:43 MDT, Station visit site 9: cleaned net radiometer
Cleaned net radiometer; found domes clean and level
- 177: GOES, Site 9, Tue 25-Jul-2006 17:55:12 MDT, Station visit site 9: data system, GOES, fence
Visited station 9 15:20 - 15:33 MST
Swapped USB disk
Taped GOES cooler; no moisture in cooler
Model 120 GOES transmitter
Repaired and tightened fence; charger okay.
- 143: data-system, Site 9, Wed 19-Jul-2006 17:03:01 MDT, St 9 Visit: GOES outage
19Jul06 14:10-14:45
Purpose: Station reporting was intermittent and then down last night/today
Upon arrival:
Station power OK
DAQ OK
usbstick OK, data was being archived.
GOES down.
No obvious reason in messages or adam.log
See adam/message logs in:
/data/projects/Cupido/logs/st9_071906_xxx.log
Reinstalled software
Just for giggles.
Did see the 'memory error' that I've seen before when doing this,
even though Gordon reports that shouldn't be a problem.
usbstick swapped
Rebooted: everything went ok and reporting started right up without
any problem, or needing power cycle, etc.
Note: Did observe data_stats 'late message received' error after the
reboot. Perhaps that had something to do with it.
- 116: LOG, Site 9, Sat 15-Jul-2006 18:01:11 MDT, St 9: Site maintenance and electric fence install
Site visit: 1432 - 1605
The net radiometer was cleaned between 1433 - and 1438.
PVC was inserted into the GOES cooler box to allow heat to escape.
An electric fence was installed.
The precip gauge was checked.
- 76: radiation, Site 9, Sat 08-Jul-2006 16:22:29 MDT, st9 Visit: Rnet leveled
8Jul06, 12:10-12:20
Purpose: Show Greg where it is,
Leveled Rnet, lifted the logger box off the ground (it was not hot because it is painted white). We also lifted the GOES xmitter off the bottom of the cooler.
Cows here now!!!
Yet another site that should have been fenced but the 'authorities'
hadn't told us. Later. I'm still thinking the risk is mostly to
the rain gauge because otherwise there is plenty of vegetation in the
area for cows to use for scratching. Same situation at 1 and 2
- 43: data-system, Site 9, Wed 05-Jul-2006 18:19:53 MDT, st9 visit: goes power level
5jul06 11:30-12:30
GOES Notes:
box here also had a bit of water in it despite being under the pv array.
SE120-3513, microstrip 9
However: measured 15W forward power!
- 42: prop-vane, Site 9, Wed 05-Jul-2006 18:18:08 MDT, st9 visit: boom angle
5jul06 11:30-12:30
Checked boom angle:
my compass = 251
rmy 'BD' = 249
i did not change the internal rmy value
- 41: data-system, Site 9, Wed 05-Jul-2006 18:14:20 MDT, st9 visit: new software
5jul06 13:15
Purpose: install new software
Data system was still running and collecting data.
Data uploaded to aster.
New software installed and the xml also