37: temp_rh, Site stn6, Tue 01-Aug-2000 17:19:59 PDT, TRH Swapped
The previous sensor was reporting bad temps (extremely high) during the
day.  The spare trh was installed.
Old: s/n 1 (ie not reporting actual board #)
New: s/n 704
Note: 704 had been reported as not working on the sbus although it was
      today.  Keep an eye on it...

PS. 3 Aug by spo:
The new sensor has been working fine.

40: temp_rh, Site stn9_marigold, Wed 02-Aug-2000 08:55:51 PDT, Profile Tower Site 09 starts operation.
7-31-00 Profile Tower University of Basel changed from intercomparison to operation.

Setup:
1 Height of booms over tower base
2 Psychrometer serial number (type Uni Basel)
3 Cup anemometer serial number (type Vector Instruments A101L)
4 Cup ID

Level 
1     0.95m   FK02 3656 / HD2
2     1.50m   FK09 3654 / HC8
3     2.35m   FK12 3390 / CW4
4     3.72m   FK13 3389 / HD0
5     6.12m   FK18 3655 / HC7
6     9.05m   FK22 3657 / HC9 Wind Vane 4729 (Vectro Instr. W200P) 



51: temp_rh, Site stn3, Fri 04-Aug-2000 19:07:23 PDT, TRH swap / Possible EVE problems
The TRH has not been working for a few days.
Arriving at station confirmed no reply on the sbusdebug.
Attempted to 'stop' eve and got:
	memPartFree: Invalid block 0x157d04 in partition 0x70392
at that point the watchdog/reset board did it's thing but the
reboot failed with the same errors
	memPartFree: Invalid block 0x16b078 in partition 0x70392
power cycling the box brought everything back up including the
trh.
To be on the safe side I swapped the trh anyway
Old TRH: #702
New TRH: #703

Possible EVE memory problem:
The trh was down during the hot part of the day during the last 4
days.
Note: This station has the eve electronics box mounted laying down
      rather than the normal upright configuration.  This could
      increase the heating on the eve boards.

62: temp_rh, Site stn8_cosmos, Sun 06-Aug-2000 19:01:34 PDT, Tsfc*4 added, sort-of
I installed the 4 tsfc infrared temp. sensors as follows:
tsfc1 at 10cm above ref. pointing south
tsfc2 at about 40 cm. pointing 30-deg out from base to north
tsfc3 at 50cm above ref. pointing north
tsfc4 at 50cm above ref. pointing south
Ref = top height of ridges.

However....
the CR10 logger is reporting all -39.00 for these values.
There appears to be a programming or wiring error based
upon where the connections are vs. the comment in the
program listing.  Unfortunately this is a CR10, not 10x
so it needs to have a prom written to retain any changes
in the program.
More later...

Note: I need to verify the 30-degree angle and the level
of the other sensors.  2 of them do not have the adjusting
knobs and tsfc3 is loose and pointing a little above horizontal.