Project #2003-303 BAMEX

Bow Echo and MCV Experiment

Christopher Davis, et al.

U.S. Naval Research Laboratory P-3 Orion


Summary of Calibration Factors



Pre-Calibration - 05/01/2003
Variable (Units) Variable Name C1 C2 C3
Total Temperature-Radome Right (C)TTRR-9.8484.991-0.0032
Total Temperature-Radome Left (C)TTRL-10.0875.152-0.0069
Dew Point Temperature-Top (C)DPT-1.3029.8840.0025
Vertical Press. Diff. Radome (mbar)ADIFR0.4605.1880.0006
Horizontal Press. Diff. Radome (mbar)BDIFR0.3735.2340.0024
Dynamic Pressure-Radome (mbar)QCR69.3366.893-0.0010
Dynamic Pressure-Fuselage (mbar)QCF86.4468.6130.0005
Static Pressure-Fuselage (mbar)PSF540.89354.211-0.0069

Post-Calibration - 07/08/2003
Variable (Units) Variable Name C1 C2 C3
Total Temperature-Radome Right (C)TTRR-9.7314.997-0.0029
Total Temperature-Radome Left (C)TTRL-10.1995.125-0.0023
Dew Point Temperature-Top (C)DPT*-0.9389.576-0.4188
Vertical Press. Diff. Radome (mbar)ADIFR*0.11710.3700.0014
Horizontal Press. Diff. Radome(mbar)BDIFR0.3625.2710.0008
Dynamic Pressure-Radome (mbar)QCR69.3356.897-0.0013
Dynamic Pressure-Fuselage (mbar)QCF86.2418.6050.0004
Static Pressure-Fuselage (mbar)PSF541.09054.176-0.0082

Differences between the Pre- and Post-Calibrations were generally within acceptable levels, thus indicating stable response from most sensors. The (*) denotes sensors that were replaced in the field. Pre-Project calibrations have been used in the final data processing, except where sensors were replaced.


Calibration Maneuvers

RAF uses sets of in-flight maneuvers specifically designed to help evaluate the performance of the 3-D wind measurement system on the aircraft. Measurement errors for the wind variables were within normal performance standards.


Last update: Fri Aug 1 15:22:00 MDT 2003