GENERAL: Anchorage has ~ 50 ppm elevated CO2 and a sharp transition on climbout ~19:28 Low over Fairbanks. Barely dipped into ~ 5 ppm CO2 increase. 20:33:58 Low over Deadhorse. ~ 3 ppm of CO2 increase. 21:21:20 Low. CO2 up by ~ 2 ppm at ~5 kft. CO and CO2 dips correlated on way down and up - saved png. Also saw CO and CO2 dip betweeen 18 and 20 kft. 22:34 At 80 N and 31 kft. turning around. AO2: At start of flight, CO2 analogue to DSM is offscale low. ~18:53:30 ~5 min after take-off, paused program and dropped co2output cutoff to 100 and added 300. ~18:55:30 ~2 min later, changed adder to 130. ~23:40:40 switched to MAN, back to SA for climb. 23:52:35 back to AUTO, starts purging LS. 00:44:15-00:44:45 blew 100 % CO2 on inlet fittings. No signal change. Looks good. MEDUSA: In preflight, tried to estimate Pup/Pdown combos for 760 torr, but did not have our inline pressure gauge available. Guessed 140/400 and 80/670. Forgot to close Box 1 flasks until after all sampling done. . . 23:45, climbing through 40 kft on flask 30, flow dropped off. 23:48 reset control to Pup = 80, Pdown = 670, waited 15 minutes to sample. ~00:20 after last sample, turned off Valve box, turned off pump, and closed flasks 1-32. ~00:29 briefly opened both upstream and downstream controllers to see passive flow and pull pressure down, then closed both controllers for a bypass line leak check (to bypass) Time Pup Pdn Pbypass 00:31:30 138 128 134 00:53 148 130 135 00:53 Started pump back up to do CO2 test, running at 80/670 through bypass at 1700 sccm. 00:54:50 powered Valve Box back up to read CO2. ~01:06:15-01:06:57 blew 100% CO2 on inlet fittings, at ~30 kft. CO2 went up by ~ 2 ppm, but also on AO2, so looks real. Another 15 sec of 100% CO2 from 01:09:10-01:09:25. Nothing on signal. Looks good. TO DO: Calibrate AO2 Li840 and adjust D/A offset Add D/A offset to AO2 stat. New MEDUSA Pup/Pdown matrix with pressure gauge. Fix MEDUSA leak thru bypass valve Inspect MEDUSA pump box rotor (and/or leakcheck for crossport) 6-way to Pump box leak on MEDUSA still exist? Fix PaSP leak on AO2. Redo checksheets. Decide on kft vs meters for targeting. Back up AO2 HD