02-Jul-95 18:50 ZDR6 Practice scans, SUR and RHIs. Calibration routines have been modified by Lutz. Two sequences may need to be activated. 21:10 Cal info: S OK, no X-band cal.
03-Jul-95 13:17 OFF SUR scans 18:00 OFF Stopped for programming changes 18:40 OFF transmitted through blanking sectors while trying to correct the software. 18:40 No cal info.
04-Jul-95 13:30 ON SUR 17:00 Stop 17:00 No calibration today -- repairing radome rip.
05-Jul-95 13:32 ON SUR 15:15 OFF RHI test pulse in data to adjust range correction 21:00 Stop 21:00 Cal info: S OK; X OK; X freq 9373.9 MHz. X trans power is 50.5 dBm; X rec'r temp = 100 deg F
06-Jul-95 13:30 OFF SUR and RHI 13:48 OFF X-Band start PIRAQ Tape P61023 14:20 S-Band start PIRAQ Tape P61123 20:00 Stop 20:20 Cal info: S OK; No X-band: PIRAQ "down"
07-Jul-95 08:00 MicroNOVA fault: No PWR "ON" indication, over-current indicator lit. Removed chassis power supply; inspected, tightened screws, re-inserted. Problem fixed. 15:27 ON S-band transmitting and record start 20:12 Stop recording 20:30 Cal info: S OK; X tx pwr=50.5 dBm; Xfreq=9373.5 ; X rec'r temp=90 F
08-Jul-95 12:00 Solar alignment check (S az +.1; S el +.09; Xhor az +.075; Xhor el +.156) 12:32 HOR SUR99 Clutter scans for Bob Rilling (12 minutes) 12:32 HOR Recording start 14:05 Changed test pulse to 3km width due to problem detected at 40dB [test pulse attenuator setting] xx:xx Observed a bad Doppler calculation of coherent test pulse with range 50, width 10, hi-pwr attenuator 40. 19:06 Stop recording 1.4 kvA UPS in radar gave a "low battery" alarm. Have modified some parameters to make it less sensitive to the GENERAC output. 19:09 Cal info: S OK; X OK; X tx pwr=50.6 dBm; Xfreq=9375.75 ; X rec'r temp=85 F
09-Jul-95 13:34 OFF Start tape recording X-band PIRAQ computer in use, so X-band data are questionable until about 13:43 13:43 PIRAQ S-band start recording 13:51 PIRAQ S/X re-start recording Rilling tower position check shows a 600m range offset between expected tower position and its processor position. Tower radar coordinates for future reference: 261.77 at 28.8km 20:19 Stop PIRAQ tapes 20:21 Stop RP6 recording 20:25 Cal info: S OK X tx pwr=50.8 dBm; Xfreq=9373.3; X rec'r temp=100 F
10-Jul-95 13:39 NO CLUT1; 100m gates clutter scans 13:58 NO CLUT2; 200m gates clutter scans 14:13 NO CLUT3; 150m gates clutter scans 14:20 NO SUR 14:39 MicroNOVA bomb; reload 15:00 YES Sector scan with Shiloh tower 15:33 NO RHI/PPI 15:47 NO RHIs dropping beams on display or on processor -- needs checking. 18:48 MicroNOVA bomb; reload 22:30 NO Stop 23:30 Cal info: S OK; X OK X tx pwr=51.5 dBm; Xfreq=9375.8; X rec'r temp=85 F
11-Jul-95 13:30 NO SUR/RHI 16:23 MicroNOVA bomb -- reset and reloaded 21:25 Stop xx:xx Cal info: S OK; X questionable X tx pwr=51.2 dBm; X rec'r temp=85 F First X-cal on tape aborted Cal done at about el=165 degrees; cable too short and used two cables to inject TP from signal generator, but only could inject +9.0 dBm. There may be clouds in TP region!
12-Jul-95 12:12 NO Start SUR 13:02 Reset pedestal servo 30 power breaker - RMS on Az faulting. 13:05 NO SUR/RHI 13:10-13:45 Reset pedestal servo breaker RMS Az fault. Slowed Az rates to 12-deg/sec, maximum. 13:55 MicroNOVA bombed in middle of RHI 15:45 MicroNOVA bombed at start of RHI (address 077001, during reloading 076514 checksum) 20:04 Stop. 22:00 Cal info: S OK; X OK X tx pwr=51.1 dBm; Xfreq=9375.85; X rec'r temp=85 F
13-Jul-95 14:29 SUR/PPI start 14:51 System restart due to multiple "fails" (REM display, no X-band O/P [?] to displays) 20:08 Stop recording 20:30 Cal info: S OK; X OK X tx pwr=51.1 dBm; Xfreq=9374.15; X rec'r temp=90 F
14-Jul-95 12:24 OFF RHI22/SUR9 13:00 test pulse shows bad Doppler; added .1 dB attenuation to TP, shows good, now. 16:08 MicroNOVA fault: 077001 16:13 System started 17:32 S-band HV over-current. Reset. No problem. 20:05 CRDS crash. Power-up reset. 20:09 Stop recording 20:50 No X-band X-mit when entering cal program. Changed housekeeping word 202 from 430 to 508, as per Wilson's instructions. 20:30 Cal info: S OK; X n/a
15-Jul-95 11:55 OFF SUR; start recording 19:30 Stop recording 19:45 Cal info: S OK; X OK X tx pwr=50.8 dBm; Xfreq=9370.25; X rec'r temp=90 F
16-Jul-95 11:48 OFF TP Doppler calculation incorrect. Set 2A1 attenuator from 040 to 042. 11:55 OFF Start recording; SUR 12:40 PIRAQ-S tape fault; would not recognize tape. Reloaded tape; OK for now. 13:12 MicroNOVA failure; reloaded program "LOADANT" 13:16 MicroNOVA checksum error. Reload. 13:20 Back online. 16:04 MicroNOVA failure. 16:09 Back online; noticed operator setting 14 deg/s scan rate. Recommended 13 or less. 19:31 Stop recording data. 20:30 Cal info: S OK; X n/a (tape problems) X tx pwr=50.8 dBm; Xfreq=9373.3; X rec'r temp=95 F
17-Jul-95 12:40 Set TP to 041. 12:42 ON Start recording 17:08 Reboot MicroNOVA 17:08 X-band transmitter power changed to 50.8 in housekeeping [this time the change worked.] 20:38 Stop xx:xx Cal info: S OK; X not OK; weather in TP X tx pwr=50.8 dBm; X rec'r temp=80 F
18-Jul-95 12:30 YES SUR 12:43 NO Tape drive problems; restarted tapes. 14:38 NO X-band power lost; restart X-band through warm-up 14:48 Stop for software change on housekeeping 14:59 No Start. RHI and SUR. 20:09 Cal info: S OK; X OK. (A few bad steps) X tx pwr=50.8 dBm; Xfreq=9375.5; X rec'r temp=85 F
19-Jul-95 12:57 YES SUR 13:08 Did a NOVA reboot (display was bad) 21:07 Stopped. 21:45 Cal info: S OK; X OK X tx pwr=50.8 dBm; Xfreq=9373.05; X rec'r temp=95 F
20-Jul-95 12:59 Run BOB4 20:36 No problems during ops. 21:00 Cal info: S OK; X OK X tx pwr=50.5 dBm; Xfreq=9374.9; X rec'r temp=85 F
21-Jul-95 13:07 Run SUR 13:25 Run RHI 14:16 BOB4 14:19 MicroNOVA crash 14:19. Reboot and rerun, 14:24 14:28 MicroNOVA crashed twice in a row. 14:33 Rerun 15:24 BOB5 16:38 MicroNOVA crash. xx:xx Cal info: S OK; X not-OK; weather in the way. X tx pwr=50.5 dBm;
22-Jul-95 13:10 BOB4 16:32 MicroNOVA crashed 16:41 Restart SUR 16:42 RHI 18:30 MicroNOVA crashed 18:39 Restart 19:05 Recording off. 19:xx Cal info: S bad; X bad X tx pwr=50.7 dBm
23-Jul-95 13:10 SUR9 18:58 Tape drive "Q" stopped. 19:02 Started new tapes 19:15 Q tape deck stopped working; left it running on the "P" drive [Tapes Q20321 and Q20322 are likely incomplete.] 20:30 Off. 20:30 Cal info: S OK; X OK X tx pwr=51.3 dBm; Xfreq=9375.6; X rec'r temp=100 F
24-Jul-95 11:57 Started ops, SUR9 "Q" tape drive stopped. Will continue with only the "P" drive until ops are over, and then replace Q. 21:31 Shut down. 21:40 Cal info: S uncertain; X uncertain (weather in TP) X tx pwr=51.2 dBm; Xfreq=9375; X rec'r temp=100 F
25-Jul-95 11:51 Start SUR9 12:15 Tape drives quit! Replaced with spare tape drives. 12:27 Started SUR9 with new tapes. 12:39 Tried to change PRF, but S-band would not work. 12:50 Started SUR9 15:15 Antenna controller crashed. 15:23 Restart 15:35 Changed PRF 16:12 Antenna controller crashed. 16:16 Restart. 16:45 Ejected tapes -- CRDS locked-up. 16:55 Restarting with new tapes. 19:41 Lost power. Restart voltage regulator. Generators switched; I don't know why. Shut down to switch power back to GENERAC. Running OK. 20:16 Start recording. 23:13 Shutdown. 23:13 Cal info: S OK; X not OK; weather in test pulse. X tx pwr=51.7 dBm; Xfreq=9376; X rec'r temp=82 F
26-Jul-95 12:22 Change PRF 1225 12:39 Running SUR 14:28 MicroNOVA crashed. 19:16 X-band off for PIRAQ PC upgrade. 20:43 MicroNOVA crash 20:48 Rerun. 22:13 Cal info: S OK; X OK X tx pwr=51.5 dBm; X rec'r temp=80 F
27-Jul-95 11:03 Run SUR 13:50 Run BOB4 19:10 MicroNOVA crashed 19:14 Rerun BOB23 19:48 Crashed. Error in task 17 reported by 80570 (called at 351334201 FORTRAN error 900) 20:12 Cal info: S OK; X n/a X tx pwr=51.7 dBm; X rec'r temp=80 F
28-Jul-95 12:08 Started SUR21 12:33 Change of PRF 720 16:45 Antenna controller crash 18:19 Stopped 18:40 Cal info: S OK; X not OK; weather in test pulse X tx pwr=50.9 dBm; Xfreq=9374; X rec'r temp=95 F
29-Jul-95 11:20 Started PPI123 11:44 MicroNOVA crash 13:23 MicroNOVA crash 13:26 Restart 14:54 S-band kicked-off 16:49 MicroNOVA crash 17:47 Shut-down 18:30 Cal info: S OK; X uncertain X tx pwr=51.2 dBm; Xfreq=9374; X rec'r temp=85 F
30-Jul-95 11:50 Start PPI23 16:02 MicroNOVA crashed 16:35 Changed PRF from 960 to 722 19:02 Tape stopped 19:05 Started new tapes 22:02 Stopped for shut-down and to change the tape drives. 22:40 Cal info: S OK; X OK; X tx pwr=51.4 dBm; Xfreq=9374; X rec'r temp=90 F
31-Jul-95 11:56 SUR 13:40 MicroNOVA crashed 13:45 BOB4 13:56 MicroNOVA crashed 13:59 Rerun BOB4 14:45 MicroNOVA crashed 14:49 Run BOB4 16:50 Cal info: S OK
01-Aug-95 13:09 SUR 14:23 RHI 14:49 MicroNOVA crash 14:56 Rerun RHI 17:26 Stopped antenna to remove the (???) 17:55 Rerun SUR9 19:02 Lost S transmitter. Reset and rerun 21:05 MicroNOVA crashed 21:42 MicroNOVA crashed 21:45 Rerun BOB23 02-Aug-95 03:23 MicroNOVA crashed 03:28 Rerun BOB23 03:43 Tape deck quit 03:45 Started new tapes 04:50 MicroNOVA crashed 04:54 Rerun BOB24 05:07 MicroNOVA crashed 07:10 Crashed 07:43 Rerun BOB23 09:25 MicroNOVA crashed 10:56 SUR9 xx:xx Running BOB23 18:12 Tape deck stopped running 18:40 Cal info: S OK; X uncertain; weather in test pulse X tx pwr=51.8 dBm; Xfreq=9376; X rec'r temp=85 F
03-Aug-95 11:28 Started ops. 12:28 Changed PRF to 720 12:31 Changed PRF to 960 12:48 MicroNOVA crashed 13:07 MicroNOVA crashed 13:32 MicroNOVA crashed 14:18 MicroNOVA crashed 14:37 MicroNOVA crashed 15:03 MicroNOVA crashed 17:14 MicroNOVA crashed 19:42 Stopped 19:45 Cal info: S OK; X OK X tx pwr=51.4 dBm; Xfreq=9375; X rec'r temp=85 F
04-Aug-95 11:24 Start ops 13:18 MicroNOVA crashed 14:05 MicroNOVA crashed 16:20 MicroNOVA crashed 17:40 MicroNOVA crashed; FORTRAN error 901 19:16 Tape decks stopped 19:18 Started new tapes 21:05 MicroNOVA crashed; FORTRAN error 901 22:23 Changed PRF to 720 00:13 Stopped 00:30 Cal info: S OK; X OK X tx pwr=51.1 dBm; Xfreq=9375; X rec'r temp=90 F
05-Aug-95 11:42 Starting PPI9 13:50 MicroNOVA crashed 17:55 Switched MicroNOVA to regulated power from UPS 19:39 Tapes stopped; ejected 19:42 Started new tapes 00:16 Stopped 00:30 Cal info: S OK; X OK X tx pwr=51.8 dBm; Xfreq=9376; X rec'r temp=87 F
06-Aug-95 12:02 SUR9 14:02 BOB4 xx:xx SUR 95 xx:xx No problems 20:00 Cal info: S OK; X OK X tx pwr=51.2 dBm; X rec'r temp=88 F
07-Aug-95 12:04 SUR9 13:30 RHI and SUR95 15:38 BOB4 18:40 SUR95 19:36 Lost S Transmit power (transmitter HV over-voltage fault light came on) 19:37 restart 19:37 do cal 19:37 Cal info: S OK; X OK X tx pwr=51.3 dBm; Xfreq=9374.3; X rec'r temp=87 F
08-Aug-95 11:53 Started SUR9 18:53 Stopped tapes 18:56 Started new tapes 22:09 Stopped 22:09 Cal info: S OK; X OK; weather in test pulse X tx pwr=51.4 dBm; Xfreq=9375.4; X rec'r temp=95 F
09-Aug-95 11:45 Started SUR9 18:53 Stopped tapes 18:56 Started new tapes 20:55 Changed PRF to 720 21:15 Stopped 21:20 Cal info: S OK; X OK X tx pwr=51.3 dBm; Xfreq=9372; X rec'r temp=90 F
10-Aug-95 11:30 Started SUR95 13:00 S-band Xmtr overcurrent and 5KV overcurrent fault 13:41 S-band Xmtr overcurrent fault 18:42 Stopped tape 18:45 Started new tapes 21:00 Stopped 21:10 Cal info: S OK; X OK X tx pwr=51.3 dBm; Xfreq=9375; X rec'r temp=110 F
11-Aug-95 11:59 SUR95 13:21 BOB4 15:03 Lost S transmitter due to "Transmitter HV overcurrent fault" 15:04 Restart OK 18:53 Stopped to change tapes 18:57 Start recording tapes 20:05 NOVA FORTRAN error 900 20:08 Rerun SUR99 and PPI99 xx:xx Cal info: S OK; X OK X tx pwr=51.4 dBm; X rec'r temp=110 F
12-Aug-95 11:54 Running SUR95 13:19 Lost TX S-band power due to "tramsitter HV overcurrent fault" 13:20 Restart BOB4 16:36 Lost TX S-band "Transmitter HV overcurrent fault" 16:37 reset and rerun 17:28 Stop TX; changed PRF 17:32 Rerun SUR9 and PPI19 18:52 Stopped scan and changed to new tapes xx:xx Added oil to Genrac generator after day's ops 20:36 Cal info: S OK; X OK X tx pwr=51.5 dBm; Xfreq=9374.7; X rec'r temp=89 F
13-Aug-95 12:01 Run SUR95 13:05 X-band transmitter went into "warm-up mode" Reset and rerun X-band 13:07 Restart bergamot computer [???] 13:38 Lost Tx (Tx HV overcurrent and 5KV over current) fault light came on. 13:39 Run BOB4 18:58 Changed tapes 19:00 Xterm window crashed; rebooted system 19:31 Rerun SUR95 xx:xx Cal info: S OK; X OK X tx pwr=51.3 dBm; X rec'r temp=110 F
14-Aug-95 11:32 Started SUR9 16:40 MicroNOVA FORTRAN error 18:36 Changed tapes 19:43 STOPPED FOR GOOD!!! 19:50 Cal info: S OK; X OK X tx pwr=51.3 dBm; Xfreq=9374.9; X rec'r temp=110 F
END of DATA LOG, CP2 SCMS-95