S-PolKa Operator's Log
S-PolKa REFRACTT06, Marshall Field Site, Colorado
May 2006 - Aug 2006
060523 Phinney
1430 CF on Test of tape and scan strategy
1747 Stopped
060524 Phinney
1515 CF on Started calibration tapes. 12-deg/sec az rate, 0.0-deg elev
1610 Stopped
060525 Pratte
1500 CF on Calibrations (Noise, Test Pulse and TX CAL Factors)
2200 Adjusted VIRAQ Gains
060526 Emmett
1500 CF on Solar Scan (special)
1509 RCUR Changed to H only
1519 Changed to 4 degree box
1545 STOPPED
060530 Pratte, Strong
1930 CF on Vertical Pointing Scans recorded in sweepfiles RAID 1
2007 Stopped Vertical Pointing Scans
060605 Emmett,Tudor
1549 CF on Started OPS
0002 Shut Down
060607 Phinney,Emmett,Pereira
1400 CF on Started OPS
2400 Stop OPS
060609 Pereira, Emmett
1530 CF on Recording Solar Box
1600 Started ops
2058 Vertical Pointing
2118 Vertical Pointing
0000 Stopped Could not get solar scan to work.
Sun was moving too fast.
060612 Pereira
1548 CF on Started OPS Running R-Early
1813 Changed Scan to REFRACTT
060613 0000 Shut Down
0002 Tried to run Solar Box
0028 Forget it [STOPPED]
060614 Pereira
1440 CF on Started ops, Running R-Early
1543 Running Solar Box - OK
1550 Running R-Early
1700 Started R-Early @ 1700 to sync with other radars
1937 Processor stopped, restarted
0000 Running Solar Box
060615 Pereira
1501 CF on Running Solar Cal
1511 Running R-Early
2000 Processor Quit - Restarted
060616 0000 Stopped ops
0001 Running Solar Box
0010 Shut Down
060616 Phinney
1332 CF on Started Solar Box
1337 Started R-Early
1500 Shut Down
1640 Start for Vert Point
1707 Running R-Early
1743 Vertical pointing
1800 Stopped Data
060619 Holden
1510 CF on Started Box Scan
1525 Started R-Early Scan
1804 Started REFRACTT Sequence
0001 Started Box Scan
0006 Quit
060621 Holden, Tudor
1500 CF on Start
1503 Start Box Scan
1517 Start R-Early Scan
1642 Start REFRACTT Sequence
2321 Vert Point
2326 Start REFRACTT Sequence
2400 Quit Ops
060622 0003 Start Sun-Box Scan
0012 Stop
060622 Tudor
1331 CF on Start Sun-box scan
1343 Start REFRACTT sequence
0000 Quit Ops
0002 Start Dun-Box Scan
0010 Stopped
060623 Phinney
1645 CF on Running for Test
1710 Off
060625 Dixon
0030 CF on Started Antenna for testing Software - No xmit
0230 Switched antenna off.
NOTE: Antenna ran in nomal, vert pointing and solar cal mode
to test data aquisition of RVP8. The transmitter was not
powered up.
060627 Phinney, Tudor
1446 CF on Start Sun-box scan
1457 Stop Sun-box scan
1505 Start R-Early
1641 Antenna stopped. re-started processor
1703:30 Stop R-Early
1704:00 Start R-Early (Trying synch with Chill.)
1909 Started REFRACTT Sequence
060628 0001 Stop REFRACTT Sequence
0001 Start Sun-box scan
0020 System shut down
060628 Phinney, Tudor
1475 CF on Start Sun-box scan
1504 Stop sun-box scan. RDA2 - not archiving
1509 RDA started archiving then stopped, tried reloading
tape - no go so re-booted computer
1517 RDA2 back up. tape archive now back on line
1523 Start R-Early
1646 Stop R-Early
1647 Start REFRACTT Sequence
060629 0000 Stop REFRACTT Sequence
0003 Start sun-box scan
0011 Stop sun-box scan
060630 Phinney, Tudor
1436 CF on Start sun-box scan
1443 Stop sun-box scan
1518 Start R-Early scans
1652 J13 cable was tweaked to bring LDR test pulse value
from 2.69 to ~3.30
1803 Started REFRACTT sequence
060701 0000 Stop REFRACTT sequence
0001 Start Sun-bos scan
0009 Stop sun-box scan
060701 Holden, Ellis
1239 CF on Start Sun-box scan
1246 Stop sun-box scan
1250 Start R-Early
1325 Started SUR-R
1458(?) Stop
0102 Solar - Changed sun-box angle rate to 1degree/sec
0116 [stopped solar scan]
060707 Emmett
1445 CF on Normal Solar Scan
1500 Box Scan
1540 Start R-Early
1754 Stop R-Early / Start Refractt
1921 Antenna hung up. Reset PMAC
060708 0000 Solar Box Angle Rate to 1 deg/sec
0005 [Solar Scans]
0018 [Stopped Solar Scans]
060708 Emmett, Strong
1228 CF on Box-Scan Solar
1308 Running Sur-r
1521 Vert pointing
1530 Running Sur-r
1537 Bos-Scan solar w/TP off
1557 Vert pointing
1700 Stopped vert pointing - Mike Dixon / Frank Pratte
1900 Shut Down - Mike Dixon / Frank Pratte
060709 0200 Mike Dixon: Vertically pointing in rain.
0300 Noticed waveguide pressure was low. Found kink in
line and freed that, pressure looks OK now. But I did
not [restart the?] radar, just in case there is still a problem.
060709 Dixon
2230 CF on Checked waveguide pressure - OK at 3 psi.
2252 Start xmitting R-EARLY scans
2257 Start recording, R-EARLY
2302 Start Vert point mode
2347 Stop data collection. Tx off.
0020 Shut down
060710 Emmett, Strong
1500 CF on Sun-Box Scan
~1530 Vert Pointing
1545 R-Early
1800 Refractt Sequence
0000 STOP
060711 Tudor
1442 CF on Start Sun-Box scan (test pulse off)
1502 Stop Sun-Box scans (test pulse turned on)
1504 Removed RDA tapes (Dennis) to swap out P tapedrive
1526 Start R-Early scans
1543 Stop R-Early scans
1543 Start vertical scan
1549 Stop vertical scan
1549 Start R-Early scans
1722 Stop R-Early scans
1722 Start REFRACTT sequence
2328 Stop REFRACTT sequence
2328 Start vertical scan (very light rain)
2334 Stop vertical scan
2334 Start REFRACTT sequence
060712 0030 Stop REFRACTT Sequence
0031 Start Sun-box scan
0040 Stop Sun-box scan
060712 Tudor
1432 CF on Start Sun-Box Scan (test pulse off)
1443 Stop Sun-box Scan (test pulse turned on)
1447 Start vertical scan
1451 Slight adjustment to test pulse
1455 Stop vertical scan
1455 Start R-Early scans
1833 Stop R-Early scans
1833 Start REFRACTT sequence
060713 0000 Stop REFRACTT Sequence
0001 Start Sun-Box Scan
0012 Stop Sun-Box scan
0017 Stop RDA's
060713 Tudor
1431 CF on Start R-Early Scan (testing new network connection
will run sun-box scan after the test)
1443 Stop R-Early scans
1443 Start Sur-R scans
1503 Stop Sur-R scans
1504 Start R-Early
1518 Stop R-Early
1519 Start REFRACTT sequence
1522 Stop REFRACTT sequence
1525 Start Sun-Box scan
060713-716 Ka-Band Install July 13-16, 2006
060717 Emmett
1911 CF on New IOP
2050 Ka Running, dish not aligned
1228 Running "Refractt" scan
2223 Switch to Gen PWR
060718 0004 Stop
0033 Vert Pointing
060718 Emmett
1518 CF off Solar Box-scan with S-Band clutter filter off
1548 CF off Solar Box-scan
1602 CF off R-Early
1608 CF on Clutter Filter ON
1733 Restart Ka Proc
2105 Running REFRACTT
0004 Stop Scan
060719 Pereira
1450 CF on Started Solar Cal - Dishes are now aligned
1610 Started R-Early, Ka band currently down.
1706 Running R-Early, Ka band still down.
1822 Running Refractt Sequence
0000 Shut down REFRACTT Scan, Running Solcar Cal
0014 Stopped RDA
060720 Pereira
1559 CF on Started ops, Solar Cal, Ka band may not be synced to GPS
1617 [Stopped Solar Cal]Running R-Early
1620 RDA1 not wriging files to tape, last tar is from
7/20/06 0012 Z. Chris B is going to try and restart
archiver process from UCAR.
1706 RDA Process restart successful. RDA1 now recording
1909 Vertical Pointing
1922 Running Refractt
2203 Running Vertical
2207 Running REFRACTT
2210 Ka-band transmitter tripped breaker - transmitter down.
2253 Ka-band back online
060721 0000 Shut Down Collections (Refractt)
0003 Performing Solar Cal, No filter
0012 [Stopped Solar Cal]
0137 CF off Dual Polar Status: No "Pointing" data at clutter target (H-only) S-only
0148 CF off Dual Polar Status: Yes "Pointing" data at clutter 295.6 deg az 3.95 deg el.
Dual Mode S-only
060721 Pereira
1505 CF off Running Morning Solar Cal, RDA2 not recording. Will
reboot after solar cal
1536 Running R-Early. Had to reboot RDA2 to restore function
1600 ALL SYSTEMS UP AND RUNNING NORMALLY
2348 Solar Box
060722 Pereira
1454 CF off Running AM Solar Cal
1514 CF on Running R-Early Ka-band still warming up
1526 Paused R-Early, waveguide pressure fault on Ka. Hi
Press Rec Down to 37psi. Adjusted to 45 psi
1537 Running R-Early, Ka-band running
2156 Ka-band crashed front end. Radar still running normally
2200 Shutting Down R-Early
2209 CF off Running PM Solar
2219 [Stopped]
060723 Emmett
1515 CF on [Start]
1525 [Solar scans]
Ks bottle @ ~1750 PSI
1555 R-Early
1651 Ka-band down for adjustment
1730 Ka-band up
2216 Running Refractt Sequence
060724 0014 CF off Sun-box Solar
1425 psi Ka bottle
0026 [Stopped]
060724 Emmett
1503 CF off Sun-box solar / Ka bottle @ 1425 PSI
1539 CF on R-Early
1710 Ka down
1717 Stopped S and Ka for Ka WG gault / leak in TX box.
1734 R-Early
1757 Switched RDA's to S-band only
1811 Running REFRACTT Sequence
~1945 RDA1/file dist to TAL not working because RAID is full
2220 Servo Amp fault, very high winds/ gusting AMP1
0001 Sun-box solar
0014 [Stopped]
060725 Emmett
1540 CF off Sunbox Solar / Ka N2 bottle 1400 PSI
1556 CF on R-early
1830 R-early/ El brake breaker popped, stuck @ 8.2deg
2038 Switching to REFRACTT Sequence
2023 Vertical
2028 back to REFRACTT
060726 0106 Vertical
0126 end Vertical [Stopped]
060726 Emmett
1512 CF on Solar Scans
1535 End Solar Scans
1539 R-early / 900 psi in Ka-bottle
1545 Ka RCVR locked
1827 Ka off/reset PC in Proc box and cycled PWR in Receiver
because Ghosting
1836 Ka on, No ghost echos
2000 Running REFRACTT
060727 0016 CF off Ka Ns ~600 PSI / sun-box solar
0033 [Stopped]
060727 Tudor
1512 CF on Solar scans
1524 End Solar Scans
1535 Start R-Early scans
2134 REFRACTT Sequence
2358 Ka band in local mode so must stow dish to reach transmitter
060728 0018 Start Sun-Box scan
0028 Stop Sun0box scan [Stopped]
060728 Tudor
1441 CF on Start sun-box scans
1443 Stopped sun-box scans. waiting for RDA's to load new tapes
1444 CF off Start sun-box scans
1456 stop sun-box scans
1512 CF on Run R-Early
060729 0000 Stop R-Early, stowing dish to reach Ka transmitter
0016 Start sun-box scan
0018 Stop sun-box. Dish not responding
0021 Start sun-box scan
0031 Stop sun-box scan - Stow dishto turn of N2
0038 Stopped RDA's
060729 Tudor
1452 CF off Start Sun-Box scans
1512 CF on Stop Sun-box scans
1522 CF on Start R-Early scans
~1900 The HVkv and MCma went to almost 0 -~0.2 indicating
some type of power flitch. Only 2 faults: Faultsum and PIPFLT
went to 1. Worked w/Gordon via phone to clear faults and
bring system up again.
1915 Ka band up again.
1924 Checked SPol test values - OK
2240 Stop R-Early scans
2242 Start REFRACTT sequence
2327 Zebu froze - had to do a hard re-boot
0030 Ka down. Stop REFRACTT sequence
0034 Start Sun-box scan
0035 CF off
0048 Stop sun-box scan
060730 Tudor
1443 CF off Start sun-box scans
1500 CF on Stop sun-box scan
1515 Start R-Early scans
1615 Test pulse values
1658 Stop R-Early scans
1658 Start SUR-R scans
1714 R-Early
1742 Noticed Ka band lost remote enabled
1859 Stop R-Early- VIRAQ processor quit - re-started
1909 Start R-Early scans (Ka band not affected.)
~2140 Switched to generator power.
~2230 RDA1 froze, stopped collecting and started Ka and S
band again. Now OK.
060731 0000 Stop R-Early scans Stow dish to get to Ka transmitter
0021 CF off Start sun-box scan
0040 Stop sun-box scan
0043 quit Ka band. [Stopped]
060731 Holden
1440 CF on Changed Tapes (RDA)
1513 Solar Scans
1525 Started R-Early
1600 Ka-band operating
060801 0130 Switched to Gen. Power
[No end time. Continuous ops through 060801]
060801 Phinney, Holden
1019 CF on All is well except RDA1 Display Keeps Stopping
1128 Started New IOP
1508 Ka Band Down
1536 Ka Band up
1915 Ka Band down, lots of problems losing lock today
1935 Processor quit
1939 Sband up ran 1000prf
2009 started 960 prf - ooops
2058 Ka band up
2320 Started REFRACTT Sequence
060802 0111 Stopped REFRACTT Seq
0114 Start Solar Scan
0135 Shut down
060802 Holden
1545 CF off [Start]
1548 New IOP
1621 Start Solar Scan
1641 Started R-Early
1645 Ka band up
1746 Restarted antenna control program
1934 Started REFRACTT Sequence
060803 0130 Shut Down. Too Late for Solars
060803 Holden
1441 CF on New IOP
1511 CF off Start Solar
1526 SBand up R-Early
1552 Ka band up
1754 Start REFRACTT Sequence
1957 Antenna stopped. Reset AMP1 Breaker, Mod-High winds
2400 Stop REFRACTT
0002 Start Solar
0015 Shut down
060804 Phinney
1500 CF on [Start]
1520 Box solars
1531 Started R-Early
1622 Ka-band down for processor changes to fix ghost echos
1639 Ka-band up again. Running new processor code
1742 Down. S-band and K-band. K-band work
1814 back up
1826 K-band down
0002 shut down
0006 Solars
060805 Pereira
1555 CF on [Start]
1605 CF off Running solar cal
1615 CF on Running R-Early
2013 Running REFRACTT
2225 Stopped REFRACTT
2227 CF off Solar Cal
2236 [Stopped]
060806 Pereira
1420 Testing Ka Band w/Gordon
1548 CF off Running Solar Cal.
1601 CF on Running R-Early
1602 Stopped scan, Ka band errored for pressure fault
1609 Running R-Early
0000 Stopping R-Early
0003 Ran Solar Cal. forgot to disable clutter filters
0011 [Stopped]
060807 Pereira
1445 CF off Running Morning Solar Cal
1538 CF on Running R-Early
060808 0023 Stopped R-Early
0028 CF off Running Solar Cal
0038 [Stopped]
060808 Emmett
1550 CF off Dennis is working on RDA1
1550 Replaced H channel LNA & TR tube. System Gain NOT CALIBRATED
1607 CF on R-Early
1628 Ka Fault --> M avg cur, HV ovr Cur / Turned down HV
from 22.6 to 22.4 KV
1654 Stop both systems to work on Ka
1710 Running R-Early
1952 Running REFRACTT Seq
2257 CF off Testing RVP3-Sun Solar Scan
2318 Sun-box solar
2334 [Stopped]
060809 Emmett
1722 CF on Running R-Early / Replaced LNA's in Ka, Not Calibrated
1905 Adjusted Ka Trig pulse ot 150ns
1918 Running REFRACTT
2009 Adjusted Ka Trig pulse to 140ns
2120 Adjusted Ka Trig pulse to 200ns
2125 Running REFRACTT Seq
060810 0008 Adjusted Ka Trig pulse ot 170ns
0017 Running REFRACTT Seq
0035 CF off RVP8-Sun Solar Cal
0051 Sunbox Solar
0103 [Stopped]
060810 Emmett
1450 CF off Ka Trig Pulse set to 190ns, no arc
1522 sunbos Solar
1543 RVP3-Sun Solar
1604 CF on Running R-Early / Ka Trig pulse to 210ns
1622 RESTARTED R-EARLY, PMAC was confused, it would move in
El every 180deg
2233 Running R-Early / stopped to adjust Ka Trig Pulse to 240ns
2343 CF off Sun-box Solar w/testpulse on (S-band)
2359 RVP8-Sun w test pulse on (S-band) 1.5 El offset
060811 0107 Ka started arcing after N2 changed, reduced to 130ns
060811 Emmett, Strong
1527 [Start]
1531 CF off Ka band Removed (transmitter)/ RVP8-Sun Solar W/TP on
1546 Sun-box Solar w/TP on
1559 CF on Running R-Early
1724 Start REFRACTT Seq
1800 Network connection lost RDA1, RDA2, Zebu. Zebu2 locked.
1930 Network restored. files written to tape
2334 CF off Stop - Sunbox Solar w/test pulse on, -2deg offset, CF off
060812 0009 RFV8 Solar w/tp, -1.5 deg offset, CF off
0020 END
[Note: antenna was parked/stowed, but processor left "on" from
060812 00:20 through about 14:20 on 060813; these data are
worthless, since the transmitter was "off". There are lots
of IDL scans for this 38-hour period!]
060814 Tudor
1505 CF off Start Sun-Box scan (TP off) Data was recorded to hard
drive over the weekend. Dennis transfered this data onto new
tape drives. Data collection from 08/12/06
1519 Stop Sun-Box scan. Antenna moved away from sun. 2
minute stand-by
1523 Start RVP8-Sun-box scan. offset -1.5 deg TPoff
1537 Stop RVP8-Sun-box scan
1541 CF on Start R-Early scans, tP on
2037 Switched to generator power
2137 running REFRACTT
2156 running VERT very light rain echo to 10km!
2201 running REFRACTT
060815 0045 CF off Stop REFRACTT, turn off clutter filter
0048 Start Sun-box scans - antenna stuck
0049 Stop sun-box scan - restart
0103 Stop sun-box scan
0106 Start RVP8 sunbox scan (offset -1.5) TP off
0117 Stop RVP8 sunbox scan / stow dish
0118 Stop RDA's
060815 Tudor
CALIBRATION MEASUREMNETS ALL MORNING SO NO MORNING SOLAR SCANS
1910 CF on Start R-Early scans
2003 Stop R-Early to save RVP8-Sun scan program
2008 Start R-Early scans
060816 0004 Stop R-Early scans
0007 CF off Start Sun-box scans TP on. Clutter Flt off -2 offset
0018 Stop Sun-box scan
0019 Start RVP8 - sun scan TP on, clutter flt off -1.5 offset
0030 Stop RVP8 Sun scan
0030 Stow dish. Stop RDA's
060816 Tudor
1506 [Start}
1518 CF off Start Sun-box scan offset = -2.0 TP on
1530 Stop sun-box scan - moved antenna ~180degs away from sun
1532 Start RVP8 sun-scan offset = -1.5 TP on
1544 Stop RVP8 sun scan - antenna moved ~180deg away from un
1546 CF on Start R-Early scans
1548 Stop R-Ealry scans - display flashing? Clicked on
TP, clicked back - flashing stopped.
1549 Start R-Early scans
~1845 Stop R-Early scans
~1845 Start REFRACTT Sequence
0000 Stop REFRACTT Sequence
0004 CF off Start Sun-box scan offset = -2.0 TP on
0016 Stop Sun-box scan
0018 Start RVP8 sun scan offset = -1.5 TP on
0031 Stop RVP8 sun scan, stow dish
0032 Stop RDA's
060817 Strong
1804 CF on Start R-Early
1848 RDA1 problem
2106 Start REFRACTT sequences
060818 0020 Sun-box scans
0040 RVP8 scans
060818 Strong
[Note: from about 060818 00:52:30 thru 060818 15:28:58,
S-Pol was in an IDL scan mode, with the processor left
"On". Sample rate was 32 samples per beam, so lots and
lots of beams were generated, but there was no reported
antenna motion. Those beams will be deleted.]
1601 CF on Start R-Early
2131 Vert Point
2137 R-Early
2252 Vert Point
2258 R-Early
2339 Stop
2340 [Solar Scans W/CF]
2355 Stopped Solar scan
2358 [End Solar Scans]
0007 [Solar Scans W/CF]
0007 CF off [Solar Scans WO/CF No end time]
060821 Tudor
1545 CF off Start Sun-box scan. Clutter filter OFF. TPon
1558 Stops sun-box scan. move antenna 180 deg. wait 2 min
1601 Start RVP8 sun scan TP on
1615 Stopo RVP8 - sun scan
1618 CF on Start R-Early scan
1941 Start REFRACTT Sequence scans
~2128 Switched to generator power
060822 0000 Stop REFRACTT Sequence
0002 CF off Start sun-box scan
0003 Stop sun-box scan - antenna went to zenith
0004 Stop - dish not moving
0007 Start sun-box scan TP on
0020 Stop sun-box scan, move antenna. wait 2 mintues
0022 Start RVP8 scan
~0026 Switched back to commercial power
0035 Stop RVP8 scan, Stow Dish
0035 Stop RDA's
060823 Phinney
1451 CF off Solar Cal
1522 CF on Solar scans
1534 Stopped Solar Scans
1540 Started ops R-Early
2351 Shutdown
0002 Box Solar
0015 RVP8 Solar
0024 [Stop]
060824 Phinney
1416 CF on [Start] RVP8 Testing and Cal Tape
1420 Running R-Early
1432 Running Solar
1441 Vertical
1449 Vertical Ca Test Pulse
1452 Running R-Early
1600 Running R-Early with "T"
1646 Running R-Early with "T" H only
1701 H only Transmit - H only receive
1729 V xmit Receiver toggling
1743 H xmit Receiver toggling
1751 Shut Down
060826 Dixon
1900 CF on Ran RVP8 only - for vertically pointing data and ZDR
calibration project. RDA's were not started
Transmitted in simultaneous mode, H & V
0145 Shutdown
060827 Dixon
0030 CF on Vert pointing scans - preparation
0130 Surveillance - simultaneous mode, switched
0143 Vert pointing - 15 - 20 dbz @/between 2 & 4 km
0210 Turn off ver scan. Stow antenna. xmitter off
060831 Phinney
1441 CF off Running Solars
1447 Stopped Solar Scans
1455 Running RVP8 Solars
1504 Started R-Early
1754 Mike Dixon called and said he had changed R-Early
Angle list (Fixed)
2012 Vertical Pointing
2019 Running R-Early
2144 Running REFRACTT Sequence
0012 Box Solars
0025 RVP8 Solars
0032 Shutdown
060919 [Logbook date is 060920. Data is 060919] Dixon
1530 CF on [Dual Polar Status: Illegible comment]
Collect wx data for CP ZDR method
Ran slow and fast antenna speeds.
wx to N - S at 1.3 - 2.2 deg
1815 Shutdown
060921 [Logbook data is 060920. Data is 060921] Dixon
COMMENT: No RDA recording. Only RVP3. testing proced.
0030 CF on Dual Polar Status: SIM MODE H/V Flag. Surveillance
0150 Ver. pointing
0210 Start sector - 330deg - 100deg. H & V mode alternately with waveguide switches
0221 Stop Sector
0225 Did 360degs, switching between H & V with waveguide switches.
0245 Shutdown
0310 Restarted surveilance. RDA's on.
0330 Shutdown
061009 Phinney, Mike, Pratte
1650 CF off Sur-R
1701 Solar Box VIRQ
1708 Stopped Solar box
1711 Solar Box RVP8
1718 Stopped Box RVP8
1718 Vert Scan
1726 Vert Scan xmtr off (Excitation disabled)
1729 Stopped
1729 60deg Vert Scan 6deg/sec
1734 Sur-R
1923 Vert Scan
1935 60deg VERT scan 6 deg/sec
1942 30deg Vert scan 6 deg/sec
1948 30deg vert scan x mtr off (Excitation disabled)
1957 30deg vert scan HV off also
2044 2deg el scan (SUR) 2044-2057. Dual Pol MITCH Switch (FAST)
2110 2deg el scan (SUR) 2116-2133 Slow ALT SUR's H, then V, using MITCH SW, etc
2135 2deg el scan (SUR) 2135- Dual Pol MITCH Switch (FAST)
2149 Vertical scans Dual Pol Fast Alt. (Shallow Rain)
2155 Shutdown
--- Jean Hurst ---
/ NCAR Earth Observing Laboratory
Created: Fri Aug 18 11:18:18 MDT 2006
Last modified: