S-PolKa Operator's Log

S-PolKa REFRACTT06, Marshall Field Site, Colorado
May 2006 - Aug 2006



060523								Phinney
	1430	CF on  Test of tape and scan strategy
	1747	       Stopped


060524 Phinney 1515 CF on Started calibration tapes. 12-deg/sec az rate, 0.0-deg elev 1610 Stopped
060525 Pratte 1500 CF on Calibrations (Noise, Test Pulse and TX CAL Factors) 2200 Adjusted VIRAQ Gains
060526 Emmett 1500 CF on Solar Scan (special) 1509 RCUR Changed to H only 1519 Changed to 4 degree box 1545 STOPPED
060530 Pratte, Strong 1930 CF on Vertical Pointing Scans recorded in sweepfiles RAID 1 2007 Stopped Vertical Pointing Scans
060605 Emmett,Tudor 1549 CF on Started OPS 0002 Shut Down
060607 Phinney,Emmett,Pereira 1400 CF on Started OPS 2400 Stop OPS
060609 Pereira, Emmett 1530 CF on Recording Solar Box 1600 Started ops 2058 Vertical Pointing 2118 Vertical Pointing 0000 Stopped Could not get solar scan to work. Sun was moving too fast.
060612 Pereira 1548 CF on Started OPS Running R-Early 1813 Changed Scan to REFRACTT 060613 0000 Shut Down 0002 Tried to run Solar Box 0028 Forget it [STOPPED]
060614 Pereira 1440 CF on Started ops, Running R-Early 1543 Running Solar Box - OK 1550 Running R-Early 1700 Started R-Early @ 1700 to sync with other radars 1937 Processor stopped, restarted 0000 Running Solar Box
060615 Pereira 1501 CF on Running Solar Cal 1511 Running R-Early 2000 Processor Quit - Restarted 060616 0000 Stopped ops 0001 Running Solar Box 0010 Shut Down
060616 Phinney 1332 CF on Started Solar Box 1337 Started R-Early 1500 Shut Down 1640 Start for Vert Point 1707 Running R-Early 1743 Vertical pointing 1800 Stopped Data
060619 Holden 1510 CF on Started Box Scan 1525 Started R-Early Scan 1804 Started REFRACTT Sequence 0001 Started Box Scan 0006 Quit
060621 Holden, Tudor 1500 CF on Start 1503 Start Box Scan 1517 Start R-Early Scan 1642 Start REFRACTT Sequence 2321 Vert Point 2326 Start REFRACTT Sequence 2400 Quit Ops 060622 0003 Start Sun-Box Scan 0012 Stop
060622 Tudor 1331 CF on Start Sun-box scan 1343 Start REFRACTT sequence 0000 Quit Ops 0002 Start Dun-Box Scan 0010 Stopped
060623 Phinney 1645 CF on Running for Test 1710 Off
060625 Dixon 0030 CF on Started Antenna for testing Software - No xmit 0230 Switched antenna off. NOTE: Antenna ran in nomal, vert pointing and solar cal mode to test data aquisition of RVP8. The transmitter was not powered up.
060627 Phinney, Tudor 1446 CF on Start Sun-box scan 1457 Stop Sun-box scan 1505 Start R-Early 1641 Antenna stopped. re-started processor 1703:30 Stop R-Early 1704:00 Start R-Early (Trying synch with Chill.) 1909 Started REFRACTT Sequence 060628 0001 Stop REFRACTT Sequence 0001 Start Sun-box scan 0020 System shut down
060628 Phinney, Tudor 1475 CF on Start Sun-box scan 1504 Stop sun-box scan. RDA2 - not archiving 1509 RDA started archiving then stopped, tried reloading tape - no go so re-booted computer 1517 RDA2 back up. tape archive now back on line 1523 Start R-Early 1646 Stop R-Early 1647 Start REFRACTT Sequence 060629 0000 Stop REFRACTT Sequence 0003 Start sun-box scan 0011 Stop sun-box scan
060630 Phinney, Tudor 1436 CF on Start sun-box scan 1443 Stop sun-box scan 1518 Start R-Early scans 1652 J13 cable was tweaked to bring LDR test pulse value from 2.69 to ~3.30 1803 Started REFRACTT sequence 060701 0000 Stop REFRACTT sequence 0001 Start Sun-bos scan 0009 Stop sun-box scan
060701 Holden, Ellis 1239 CF on Start Sun-box scan 1246 Stop sun-box scan 1250 Start R-Early 1325 Started SUR-R 1458(?) Stop 0102 Solar - Changed sun-box angle rate to 1degree/sec 0116 [stopped solar scan]
060707 Emmett 1445 CF on Normal Solar Scan 1500 Box Scan 1540 Start R-Early 1754 Stop R-Early / Start Refractt 1921 Antenna hung up. Reset PMAC 060708 0000 Solar Box Angle Rate to 1 deg/sec 0005 [Solar Scans] 0018 [Stopped Solar Scans]
060708 Emmett, Strong 1228 CF on Box-Scan Solar 1308 Running Sur-r 1521 Vert pointing 1530 Running Sur-r 1537 Bos-Scan solar w/TP off 1557 Vert pointing 1700 Stopped vert pointing - Mike Dixon / Frank Pratte 1900 Shut Down - Mike Dixon / Frank Pratte 060709 0200 Mike Dixon: Vertically pointing in rain. 0300 Noticed waveguide pressure was low. Found kink in line and freed that, pressure looks OK now. But I did not [restart the?] radar, just in case there is still a problem.
060709 Dixon 2230 CF on Checked waveguide pressure - OK at 3 psi. 2252 Start xmitting R-EARLY scans 2257 Start recording, R-EARLY 2302 Start Vert point mode 2347 Stop data collection. Tx off. 0020 Shut down
060710 Emmett, Strong 1500 CF on Sun-Box Scan ~1530 Vert Pointing 1545 R-Early 1800 Refractt Sequence 0000 STOP
060711 Tudor 1442 CF on Start Sun-Box scan (test pulse off) 1502 Stop Sun-Box scans (test pulse turned on) 1504 Removed RDA tapes (Dennis) to swap out P tapedrive 1526 Start R-Early scans 1543 Stop R-Early scans 1543 Start vertical scan 1549 Stop vertical scan 1549 Start R-Early scans 1722 Stop R-Early scans 1722 Start REFRACTT sequence 2328 Stop REFRACTT sequence 2328 Start vertical scan (very light rain) 2334 Stop vertical scan 2334 Start REFRACTT sequence 060712 0030 Stop REFRACTT Sequence 0031 Start Sun-box scan 0040 Stop Sun-box scan
060712 Tudor 1432 CF on Start Sun-Box Scan (test pulse off) 1443 Stop Sun-box Scan (test pulse turned on) 1447 Start vertical scan 1451 Slight adjustment to test pulse 1455 Stop vertical scan 1455 Start R-Early scans 1833 Stop R-Early scans 1833 Start REFRACTT sequence 060713 0000 Stop REFRACTT Sequence 0001 Start Sun-Box Scan 0012 Stop Sun-Box scan 0017 Stop RDA's
060713 Tudor 1431 CF on Start R-Early Scan (testing new network connection will run sun-box scan after the test) 1443 Stop R-Early scans 1443 Start Sur-R scans 1503 Stop Sur-R scans 1504 Start R-Early 1518 Stop R-Early 1519 Start REFRACTT sequence 1522 Stop REFRACTT sequence 1525 Start Sun-Box scan
060713-716 Ka-Band Install July 13-16, 2006
060717 Emmett 1911 CF on New IOP 2050 Ka Running, dish not aligned 1228 Running "Refractt" scan 2223 Switch to Gen PWR 060718 0004 Stop 0033 Vert Pointing
060718 Emmett 1518 CF off Solar Box-scan with S-Band clutter filter off 1548 CF off Solar Box-scan 1602 CF off R-Early 1608 CF on Clutter Filter ON 1733 Restart Ka Proc 2105 Running REFRACTT 0004 Stop Scan
060719 Pereira 1450 CF on Started Solar Cal - Dishes are now aligned 1610 Started R-Early, Ka band currently down. 1706 Running R-Early, Ka band still down. 1822 Running Refractt Sequence 0000 Shut down REFRACTT Scan, Running Solcar Cal 0014 Stopped RDA
060720 Pereira 1559 CF on Started ops, Solar Cal, Ka band may not be synced to GPS 1617 [Stopped Solar Cal]Running R-Early 1620 RDA1 not wriging files to tape, last tar is from 7/20/06 0012 Z. Chris B is going to try and restart archiver process from UCAR. 1706 RDA Process restart successful. RDA1 now recording 1909 Vertical Pointing 1922 Running Refractt 2203 Running Vertical 2207 Running REFRACTT 2210 Ka-band transmitter tripped breaker - transmitter down. 2253 Ka-band back online 060721 0000 Shut Down Collections (Refractt) 0003 Performing Solar Cal, No filter 0012 [Stopped Solar Cal] 0137 CF off Dual Polar Status: No "Pointing" data at clutter target (H-only) S-only 0148 CF off Dual Polar Status: Yes "Pointing" data at clutter 295.6 deg az 3.95 deg el. Dual Mode S-only
060721 Pereira 1505 CF off Running Morning Solar Cal, RDA2 not recording. Will reboot after solar cal 1536 Running R-Early. Had to reboot RDA2 to restore function 1600 ALL SYSTEMS UP AND RUNNING NORMALLY 2348 Solar Box
060722 Pereira 1454 CF off Running AM Solar Cal 1514 CF on Running R-Early Ka-band still warming up 1526 Paused R-Early, waveguide pressure fault on Ka. Hi Press Rec Down to 37psi. Adjusted to 45 psi 1537 Running R-Early, Ka-band running 2156 Ka-band crashed front end. Radar still running normally 2200 Shutting Down R-Early 2209 CF off Running PM Solar 2219 [Stopped]
060723 Emmett 1515 CF on [Start] 1525 [Solar scans] Ks bottle @ ~1750 PSI 1555 R-Early 1651 Ka-band down for adjustment 1730 Ka-band up 2216 Running Refractt Sequence 060724 0014 CF off Sun-box Solar 1425 psi Ka bottle 0026 [Stopped]
060724 Emmett 1503 CF off Sun-box solar / Ka bottle @ 1425 PSI 1539 CF on R-Early 1710 Ka down 1717 Stopped S and Ka for Ka WG gault / leak in TX box. 1734 R-Early 1757 Switched RDA's to S-band only 1811 Running REFRACTT Sequence ~1945 RDA1/file dist to TAL not working because RAID is full 2220 Servo Amp fault, very high winds/ gusting AMP1 0001 Sun-box solar 0014 [Stopped]
060725 Emmett 1540 CF off Sunbox Solar / Ka N2 bottle 1400 PSI 1556 CF on R-early 1830 R-early/ El brake breaker popped, stuck @ 8.2deg 2038 Switching to REFRACTT Sequence 2023 Vertical 2028 back to REFRACTT 060726 0106 Vertical 0126 end Vertical [Stopped]
060726 Emmett 1512 CF on Solar Scans 1535 End Solar Scans 1539 R-early / 900 psi in Ka-bottle 1545 Ka RCVR locked 1827 Ka off/reset PC in Proc box and cycled PWR in Receiver because Ghosting 1836 Ka on, No ghost echos 2000 Running REFRACTT 060727 0016 CF off Ka Ns ~600 PSI / sun-box solar 0033 [Stopped]
060727 Tudor 1512 CF on Solar scans 1524 End Solar Scans 1535 Start R-Early scans 2134 REFRACTT Sequence 2358 Ka band in local mode so must stow dish to reach transmitter 060728 0018 Start Sun-Box scan 0028 Stop Sun0box scan [Stopped]
060728 Tudor 1441 CF on Start sun-box scans 1443 Stopped sun-box scans. waiting for RDA's to load new tapes 1444 CF off Start sun-box scans 1456 stop sun-box scans 1512 CF on Run R-Early 060729 0000 Stop R-Early, stowing dish to reach Ka transmitter 0016 Start sun-box scan 0018 Stop sun-box. Dish not responding 0021 Start sun-box scan 0031 Stop sun-box scan - Stow dishto turn of N2 0038 Stopped RDA's
060729 Tudor 1452 CF off Start Sun-Box scans 1512 CF on Stop Sun-box scans 1522 CF on Start R-Early scans ~1900 The HVkv and MCma went to almost 0 -~0.2 indicating some type of power flitch. Only 2 faults: Faultsum and PIPFLT went to 1. Worked w/Gordon via phone to clear faults and bring system up again. 1915 Ka band up again. 1924 Checked SPol test values - OK 2240 Stop R-Early scans 2242 Start REFRACTT sequence 2327 Zebu froze - had to do a hard re-boot 0030 Ka down. Stop REFRACTT sequence 0034 Start Sun-box scan 0035 CF off 0048 Stop sun-box scan
060730 Tudor 1443 CF off Start sun-box scans 1500 CF on Stop sun-box scan 1515 Start R-Early scans 1615 Test pulse values 1658 Stop R-Early scans 1658 Start SUR-R scans 1714 R-Early 1742 Noticed Ka band lost remote enabled 1859 Stop R-Early- VIRAQ processor quit - re-started 1909 Start R-Early scans (Ka band not affected.) ~2140 Switched to generator power. ~2230 RDA1 froze, stopped collecting and started Ka and S band again. Now OK. 060731 0000 Stop R-Early scans Stow dish to get to Ka transmitter 0021 CF off Start sun-box scan 0040 Stop sun-box scan 0043 quit Ka band. [Stopped]
060731 Holden 1440 CF on Changed Tapes (RDA) 1513 Solar Scans 1525 Started R-Early 1600 Ka-band operating 060801 0130 Switched to Gen. Power [No end time. Continuous ops through 060801]
060801 Phinney, Holden 1019 CF on All is well except RDA1 Display Keeps Stopping 1128 Started New IOP 1508 Ka Band Down 1536 Ka Band up 1915 Ka Band down, lots of problems losing lock today 1935 Processor quit 1939 Sband up ran 1000prf 2009 started 960 prf - ooops 2058 Ka band up 2320 Started REFRACTT Sequence 060802 0111 Stopped REFRACTT Seq 0114 Start Solar Scan 0135 Shut down
060802 Holden 1545 CF off [Start] 1548 New IOP 1621 Start Solar Scan 1641 Started R-Early 1645 Ka band up 1746 Restarted antenna control program 1934 Started REFRACTT Sequence 060803 0130 Shut Down. Too Late for Solars
060803 Holden 1441 CF on New IOP 1511 CF off Start Solar 1526 SBand up R-Early 1552 Ka band up 1754 Start REFRACTT Sequence 1957 Antenna stopped. Reset AMP1 Breaker, Mod-High winds 2400 Stop REFRACTT 0002 Start Solar 0015 Shut down
060804 Phinney 1500 CF on [Start] 1520 Box solars 1531 Started R-Early 1622 Ka-band down for processor changes to fix ghost echos 1639 Ka-band up again. Running new processor code 1742 Down. S-band and K-band. K-band work 1814 back up 1826 K-band down 0002 shut down 0006 Solars
060805 Pereira 1555 CF on [Start] 1605 CF off Running solar cal 1615 CF on Running R-Early 2013 Running REFRACTT 2225 Stopped REFRACTT 2227 CF off Solar Cal 2236 [Stopped]
060806 Pereira 1420 Testing Ka Band w/Gordon 1548 CF off Running Solar Cal. 1601 CF on Running R-Early 1602 Stopped scan, Ka band errored for pressure fault 1609 Running R-Early 0000 Stopping R-Early 0003 Ran Solar Cal. forgot to disable clutter filters 0011 [Stopped]
060807 Pereira 1445 CF off Running Morning Solar Cal 1538 CF on Running R-Early 060808 0023 Stopped R-Early 0028 CF off Running Solar Cal 0038 [Stopped]
060808 Emmett 1550 CF off Dennis is working on RDA1 1550 Replaced H channel LNA & TR tube. System Gain NOT CALIBRATED 1607 CF on R-Early 1628 Ka Fault --> M avg cur, HV ovr Cur / Turned down HV from 22.6 to 22.4 KV 1654 Stop both systems to work on Ka 1710 Running R-Early 1952 Running REFRACTT Seq 2257 CF off Testing RVP3-Sun Solar Scan 2318 Sun-box solar 2334 [Stopped]
060809 Emmett 1722 CF on Running R-Early / Replaced LNA's in Ka, Not Calibrated 1905 Adjusted Ka Trig pulse ot 150ns 1918 Running REFRACTT 2009 Adjusted Ka Trig pulse to 140ns 2120 Adjusted Ka Trig pulse to 200ns 2125 Running REFRACTT Seq 060810 0008 Adjusted Ka Trig pulse ot 170ns 0017 Running REFRACTT Seq 0035 CF off RVP8-Sun Solar Cal 0051 Sunbox Solar 0103 [Stopped]
060810 Emmett 1450 CF off Ka Trig Pulse set to 190ns, no arc 1522 sunbos Solar 1543 RVP3-Sun Solar 1604 CF on Running R-Early / Ka Trig pulse to 210ns 1622 RESTARTED R-EARLY, PMAC was confused, it would move in El every 180deg 2233 Running R-Early / stopped to adjust Ka Trig Pulse to 240ns 2343 CF off Sun-box Solar w/testpulse on (S-band) 2359 RVP8-Sun w test pulse on (S-band) 1.5 El offset 060811 0107 Ka started arcing after N2 changed, reduced to 130ns
060811 Emmett, Strong 1527 [Start] 1531 CF off Ka band Removed (transmitter)/ RVP8-Sun Solar W/TP on 1546 Sun-box Solar w/TP on 1559 CF on Running R-Early 1724 Start REFRACTT Seq 1800 Network connection lost RDA1, RDA2, Zebu. Zebu2 locked. 1930 Network restored. files written to tape 2334 CF off Stop - Sunbox Solar w/test pulse on, -2deg offset, CF off 060812 0009 RFV8 Solar w/tp, -1.5 deg offset, CF off 0020 END [Note: antenna was parked/stowed, but processor left "on" from 060812 00:20 through about 14:20 on 060813; these data are worthless, since the transmitter was "off". There are lots of IDL scans for this 38-hour period!]
060814 Tudor 1505 CF off Start Sun-Box scan (TP off) Data was recorded to hard drive over the weekend. Dennis transfered this data onto new tape drives. Data collection from 08/12/06 1519 Stop Sun-Box scan. Antenna moved away from sun. 2 minute stand-by 1523 Start RVP8-Sun-box scan. offset -1.5 deg TPoff 1537 Stop RVP8-Sun-box scan 1541 CF on Start R-Early scans, tP on 2037 Switched to generator power 2137 running REFRACTT 2156 running VERT very light rain echo to 10km! 2201 running REFRACTT 060815 0045 CF off Stop REFRACTT, turn off clutter filter 0048 Start Sun-box scans - antenna stuck 0049 Stop sun-box scan - restart 0103 Stop sun-box scan 0106 Start RVP8 sunbox scan (offset -1.5) TP off 0117 Stop RVP8 sunbox scan / stow dish 0118 Stop RDA's
060815 Tudor CALIBRATION MEASUREMNETS ALL MORNING SO NO MORNING SOLAR SCANS 1910 CF on Start R-Early scans 2003 Stop R-Early to save RVP8-Sun scan program 2008 Start R-Early scans 060816 0004 Stop R-Early scans 0007 CF off Start Sun-box scans TP on. Clutter Flt off -2 offset 0018 Stop Sun-box scan 0019 Start RVP8 - sun scan TP on, clutter flt off -1.5 offset 0030 Stop RVP8 Sun scan 0030 Stow dish. Stop RDA's
060816 Tudor 1506 [Start} 1518 CF off Start Sun-box scan offset = -2.0 TP on 1530 Stop sun-box scan - moved antenna ~180degs away from sun 1532 Start RVP8 sun-scan offset = -1.5 TP on 1544 Stop RVP8 sun scan - antenna moved ~180deg away from un 1546 CF on Start R-Early scans 1548 Stop R-Ealry scans - display flashing? Clicked on TP, clicked back - flashing stopped. 1549 Start R-Early scans ~1845 Stop R-Early scans ~1845 Start REFRACTT Sequence 0000 Stop REFRACTT Sequence 0004 CF off Start Sun-box scan offset = -2.0 TP on 0016 Stop Sun-box scan 0018 Start RVP8 sun scan offset = -1.5 TP on 0031 Stop RVP8 sun scan, stow dish 0032 Stop RDA's
060817 Strong 1804 CF on Start R-Early 1848 RDA1 problem 2106 Start REFRACTT sequences 060818 0020 Sun-box scans 0040 RVP8 scans
060818 Strong [Note: from about 060818 00:52:30 thru 060818 15:28:58, S-Pol was in an IDL scan mode, with the processor left "On". Sample rate was 32 samples per beam, so lots and lots of beams were generated, but there was no reported antenna motion. Those beams will be deleted.] 1601 CF on Start R-Early 2131 Vert Point 2137 R-Early 2252 Vert Point 2258 R-Early 2339 Stop 2340 [Solar Scans W/CF] 2355 Stopped Solar scan 2358 [End Solar Scans] 0007 [Solar Scans W/CF] 0007 CF off [Solar Scans WO/CF No end time]
060821 Tudor 1545 CF off Start Sun-box scan. Clutter filter OFF. TPon 1558 Stops sun-box scan. move antenna 180 deg. wait 2 min 1601 Start RVP8 sun scan TP on 1615 Stopo RVP8 - sun scan 1618 CF on Start R-Early scan 1941 Start REFRACTT Sequence scans ~2128 Switched to generator power 060822 0000 Stop REFRACTT Sequence 0002 CF off Start sun-box scan 0003 Stop sun-box scan - antenna went to zenith 0004 Stop - dish not moving 0007 Start sun-box scan TP on 0020 Stop sun-box scan, move antenna. wait 2 mintues 0022 Start RVP8 scan ~0026 Switched back to commercial power 0035 Stop RVP8 scan, Stow Dish 0035 Stop RDA's
060823 Phinney 1451 CF off Solar Cal 1522 CF on Solar scans 1534 Stopped Solar Scans 1540 Started ops R-Early 2351 Shutdown 0002 Box Solar 0015 RVP8 Solar 0024 [Stop]
060824 Phinney 1416 CF on [Start] RVP8 Testing and Cal Tape 1420 Running R-Early 1432 Running Solar 1441 Vertical 1449 Vertical Ca Test Pulse 1452 Running R-Early 1600 Running R-Early with "T" 1646 Running R-Early with "T" H only 1701 H only Transmit - H only receive 1729 V xmit Receiver toggling 1743 H xmit Receiver toggling 1751 Shut Down
060826 Dixon 1900 CF on Ran RVP8 only - for vertically pointing data and ZDR calibration project. RDA's were not started Transmitted in simultaneous mode, H & V 0145 Shutdown
060827 Dixon 0030 CF on Vert pointing scans - preparation 0130 Surveillance - simultaneous mode, switched 0143 Vert pointing - 15 - 20 dbz @/between 2 & 4 km 0210 Turn off ver scan. Stow antenna. xmitter off
060831 Phinney 1441 CF off Running Solars 1447 Stopped Solar Scans 1455 Running RVP8 Solars 1504 Started R-Early 1754 Mike Dixon called and said he had changed R-Early Angle list (Fixed) 2012 Vertical Pointing 2019 Running R-Early 2144 Running REFRACTT Sequence 0012 Box Solars 0025 RVP8 Solars 0032 Shutdown
060919 [Logbook date is 060920. Data is 060919] Dixon 1530 CF on [Dual Polar Status: Illegible comment] Collect wx data for CP ZDR method Ran slow and fast antenna speeds. wx to N - S at 1.3 - 2.2 deg 1815 Shutdown
060921 [Logbook data is 060920. Data is 060921] Dixon COMMENT: No RDA recording. Only RVP3. testing proced. 0030 CF on Dual Polar Status: SIM MODE H/V Flag. Surveillance 0150 Ver. pointing 0210 Start sector - 330deg - 100deg. H & V mode alternately with waveguide switches 0221 Stop Sector 0225 Did 360degs, switching between H & V with waveguide switches. 0245 Shutdown 0310 Restarted surveilance. RDA's on. 0330 Shutdown
061009 Phinney, Mike, Pratte 1650 CF off Sur-R 1701 Solar Box VIRQ 1708 Stopped Solar box 1711 Solar Box RVP8 1718 Stopped Box RVP8 1718 Vert Scan 1726 Vert Scan xmtr off (Excitation disabled) 1729 Stopped 1729 60deg Vert Scan 6deg/sec 1734 Sur-R 1923 Vert Scan 1935 60deg VERT scan 6 deg/sec 1942 30deg Vert scan 6 deg/sec 1948 30deg vert scan x mtr off (Excitation disabled) 1957 30deg vert scan HV off also 2044 2deg el scan (SUR) 2044-2057. Dual Pol MITCH Switch (FAST) 2110 2deg el scan (SUR) 2116-2133 Slow ALT SUR's H, then V, using MITCH SW, etc 2135 2deg el scan (SUR) 2135- Dual Pol MITCH Switch (FAST) 2149 Vertical scans Dual Pol Fast Alt. (Shallow Rain) 2155 Shutdown

--- Jean Hurst --- / NCAR Earth Observing Laboratory
Created: Fri Aug 18 11:18:18 MDT 2006
Last modified: